4
4 - 10
HIC +
HIC
U
V
W
HIC +
Between terminals Resistance
HIC +
HIC +
HIC +
HIC
HIC
HIC
HIC
U
V
W
U
V
W
Resistance
200 k or more
300 k or more
300 k or more
300 k or more
200 k or more
200 k or more
200 k or more
No
Yes
Replace outdoor unit
control PCB.
(3) [Alarm E31]
(communications
trouble within unit)
IGBT short-circuit protection
Is E31
displayed even after
the power voltage
is reset?
Normal
CR-HIC280A
(125 Type)
CR-HIC80A
(71, 100 Type)
HIC
HIC +
U
V
W
04-309 Sanyo-4 10/27/04 1:48 PM Page 10