EasyManua.ls Logo

Technics SA-EX310 - Page 12

Technics SA-EX310
45 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SA-EX310
Likely faulty block if the normal
TP CD player Tape deck AF oscillator waveform shown at the left is not
present.
C1 Dolby pro logic block
IC1001 and IC1002 & area
S1
0.5msec 1V 1msec 100mV 1msec 200mV
C2 Master volume block VR501 &
area
S2
0.5msec 200mV 1msec 20mV 1msec 50mV
C3 Tone control block IC551 & area
S3
0.5msec 200mV* 1msec 500mV 1msec 1V
( )
( )
B
Run the tape deck
Run the AF oscillatorRun the CD player
QZZCLA
315Hz, 0dB
( )
Oscillator output
at 500Hz, 200mV
SZZP1054C/first program
1kHz, 0dB
A
Using the Oscilloscope, check the output waveforms at the test points on
the circuit boards in the following order :
(C1,S1) (C2,S2) (C3,S3) (C4,S4) (C5,S5).
To exit the service mode, power off the unit.
TEST POINTS POSITIONS OF SOURROUND CIRCUIT
NORMAL WAVEFORMS OF AMPLIFIER CIRCUIT AND LIKELY FAULTY BLOCKS
PANEL P.C.B. ( component side )
Note: Connect the '+' probe of
the oscilloscope to each
test point and the ''
probe to chassis ground.
MAIN P.C.B. ( component side )
C1
S1
S3
C3
C4
+
+
C604
C603
J22
J21
J313
J316
S4
C5
S5
J246
J245
S2
+
C551
R552
C2

Other manuals for Technics SA-EX310