Measuring
Instruments
and
Special
Tools
*
Test
discs
Allen
wrench
(M2.0)
(SZZP1101C)
1.
Playability
test
disc
(SZZP1054C)
*
Lock
paint
(RZZOLO1)
2.
Uneven
test
disc
(SZZP1056C)
%
Musical
program
disc
(ordinary)
%
Dual-beam
oscilloscope
with
bandwidth
of
30MHz
‘or
better
(with
EXT.
trigger
and
1:1
probe).
PREPARATION
1,
Remove
the
cabinet
and
front
panel
ass'y
(refer
to
“disassembly
instructions”
Ref.
No.
1,
2).
2,
Set the
power
switch
to
ON
and
press
the
open/
close
key
to
close
the
loading
drawer.
3.
Press
the
play
key
and
when
the
traverse
deck
reaches
it’s
height
position,
set
the
power
switch
to
OFF.
4,
Remove
the
tray
ass’y
(refer
to
“disassembly
instruc-
tions”
Ref.
No.
5).
5.
Remove
the
clamp
plate,
fixed
plate,
magnet
and
clamper
(refer
to
“disassembly
instructions”
Ref.
No.
10,
11).
6.
Place
the
test
disc
and
secure
it
by
using
clamper
ass'y.
(Refer
to
Fig.
1)
(refer
to
“disassembly
Instructions”
Ref.
No.
11).
the
test
mode
as
follows:
EI
keys
(3
keys)
on
‘Clamper
ass'y
Test
{hold
the
EJ
and
set
the
power
switch
to
O!
8.
Press
the
key
and
play
the
test
disc.
9.
Follow
the
adjustment
procedure.
(1)
MECHANICAL ADJUSTMENT
1.
Connect
the
oscilloscope's
CH.
1
probe
across
(VREF)
on
the
servo
P.C.B.
to
Fig.
3
on
page
27)
Oscilloscope
setting:
VOLT.
LASSER
TYAN
LAVA
WWW
OIE
200mV
SWEEP.
Sus.
Input
coupling......
AC
2.
Switch
the
player
power
ON,
and
play
track
19
on
the
test
disc
(SZZP1056C).
(Playing
any
other
track
will
prevent
the
HEX
screws
from
being
accessed.)
3.
Leave
the
player
in
play
mode
and
place
it
as
shown
ig.
3.
4.
Alternately
adjust
the
two
HEX
screws
with
the
2.0mm
allen
wrench
(SZZP1101C)
until
the
vertical
fluctuation
of
RF
signal
is
minimized
and
the
eye
pattern
is
most
stretched.
(Refer
to
Fig.
2)
5.
After
completing
the
adjustment,
lock
the
HEX
‘screws
with lock
paint
(RZZOLO1).
SL-PD687
(2)
CHECK
OF
PLAY
OPERATION
AFTER
ADJUSTMENT
%*
Checking
Skip
Search
|.
Play
an
ordinary
musical
program
disc.
%*
Checking
Playability
No
1.
Play
the
07mm
black
dat
and
the
0.2m
2.
Press
the
skip
Dutton
to
cheek
for
formal
skip
search
wedge
on
the
playability
test
disc
(SZZP
10546)
operation
(In
both
the
forward
and
reverse
direc:
and
verlty
that
no
sound
skip
or
nolse
occurs.
tlons).
2
ne
nine
tracks
of
the
uneven
test
isc
(SZZP1056C)
and
verify
that
no
sound
*
Checking
Manual
Search
skip
or
noise
occurs.
1,
Play
an
ordinary
musical
program
disc.
2.
Press
the
manual
search
button
to
check
for
smooth
‘manual
search
operations
at
either
low
or
high
speed
{in
both
the
forward
and
reverse
directions).
Hole
for
mechanical
adjustment
Hex
screws
Note:
‘The
elevation
angle
can
be
adjusted
through
this
pot
only
after
track
19
‘on
the
SZZPIOS6C
test
disc
has
been
played.
(VREF)
Allen
wrench
(SZZP1101C)
Fig.
3

Related product manuals