7
Electrical installation
The electrical installation to which the machine is connected must be in compliance with standards
and the electrical work required must be carried out by a qualified electrician. An efficient electrical
installation with adequate earth is of primary importance to ensure trouble-free operation of your
machine.
We recommend installation of a suitable wall mounted differential circuit-breaker. See table (A) for power
supply and absorption data
Check that the power supply is correct for the machine details as indicated on the plate (see page 6).
The machine’s power cable has 4 wires: the yellow/green wire is the earth the other three are the three
phases.
Table (A)
FREEZER 200/1
220 V
50 Hz
220 V
60 Hz
200 V
50/60Hz
400 V
60 Hz
380 V
50 Hz
415 V
50Hz
Total power kW.
8,9
8,9
8,9
Max absorption A.
34
22
22
Power cable
N° of wires and cross section
4 x 6
mm²
4 x 6
mm²
4 x 2,5
mm²
4 x 2,5
mm²
4 x 2,5
mm²
TECHNOGEL DISCLAIMS ALL RESPONSIBILITY FOR DAMAGE ARISING FROM INCORRECT
ELECTRICAL INSTALLATION OR FAULTS IN THE POWER SUPPLY