Machine start up
- SENSE OF ROTATION CHECK
After connecting the machine electrically and hydraulically, and connecting the voltage, carry out the following
operations:
A) press the START push button (1) and the control panel (console) will light up.
B) press the ON push button (2) and the mixer (3) will start.
The mixer must be turning clockwise. If it is not, then:
C) stop the mixer (3) by pressing the OFF (4) push button.
D) disconnect the tension from the control panel (console) by pressing the START (1) push
button
E) pull the plug out of the socket and invert any two of the three phases
F) try again starting from point (A).
Safety warning
ATTENTION!! IF YOU OPEN THE COVER (5), THE MIXER (3) STOP
The machine is in working condition only when the cover (5) is placed and closed.