7. Preparing for use
IMPORTANT
Scubatech / Tecline recommends delivering a demand regulator to an
Authorized Scubatech / Tecline Dealer for connecting accessories such as:
pressure measurement device, medium pressure tubes and second pressure
reduction stages of demand regulators. An Authorized Scubatech / Tecline
Dealer may also answer to questions regarding the issues presented in these
instructions.
For proper preparing a demand regulator for use, the following steps must be
performed:
equip a demand regulator with a device monitoring gas pressure in a
cylinder/twinset,
check if a demand regulator kit is complete,
IMPORTANT
Connecting medium pressure hoses to high pressure outputs and using any
connections between medium and high pressure hoses
is forbidden.
arrange properly medium pressure feeding hoses: buoyancy compensator, dry
suit, etc.
visually inspect the demand regulator's condition,
check if all connections and a mouthpiece are assembled properly,
test for tightness under pressure in the following way:
o insert the mouthpiece of the second-staged demand regulator to your
mouth,
o clog the air inlet to the first-staged demand regulator,
o take a breath through the second-staged demand regulator,
o if taking a breath in such is now impossible the demand regulators is
tight.
IMPORTANT
Before screwing a demand regulator to a diving cylinder/twinset please verify if
the tank valve is unobstructed and clean. Check if there is o-ring in the
pressure reducer’s ferrule and check its condition. If it is damaged or worn out,
it must be obligatorily replaced.
screw the demand regulator to the diving cylinder's/twinset's seat, lightly
tightening, do not apply too much force,
slowly open the cylinder's valve (valves),
CAUTION
When opening the cylinder's/twinset's valve, the safety valve of the pressure
gauge should not be directed towards a user or other persons in case of its
malfunctioning.