PROVASET 2P code 2P2B00 - 2P6B00 - Instruction manual
rev. 14/02/2013
page 24
Parameter ENABLE FOR TEST OBSTRUCTION
NO : Obstruction test disabled
YES : Obstruction test enabled
Parameter FINAL PRESSURE DISCHARGE
You are asked to enable or not the automatic air discharge in the tested piece at the test
end.
NO: Pressure discharge disabled: the tested part remains under pressure at end of test;
YES: Pressure discharge enabled: at the end of test the valves are automatically opened
to drain to discharge the pressure inside the tested part;
Only for 2P2B00 model
MAN: Manual pressure discharge:
the pressure is discharged inside the tested part only when the operator
disconnects the part from the equipment;
if the test was passed, the green light turns off and the display changes to the
message indicating ready for a new start with the selected test table.
Parameter BUZZER
xx: Duration of the sound signal at the test end in case of error or failed result.
Range 0 ÷ 99 seconds.
Parameters PROGRAMMING
NO : Programming disabled
YES : Programming enabled