SMOKE E FIRE OCCURRENCE
8. SMOKE AND FIRE OCCURRENCE
8.1 ENGINE FIRE ON THE GROUND
1. Fuel Selectors BOTH OFF
2. Ignitions ALL OFF
3. Electrical fuel pumps BOTH OFF
4. Cabin heat and defrost OFF
5. MASTER SWITCH OFF
6. Parking Brake ENGAGED
7. Aircraft Evacuation carry out immediately
WARNING
Consider use of ditching emergency exit to escape in case pilot
or passenger doors are blocked, watch for engine hot parts,
fuel, hydraulic fluid or oil spills. Leave aircraft in upwind di-
rection.