Section 2 – Limitations
FLIGHT CONDITIONS
19. FLIGHT CONDITIONS
The aircraft can be equipped for following flight operations (make reference to Pa-
ra. 22 concerning the equipment list required on board to allow them):
VFR Day and Night
IFR Day and Night including IMC
Flight in expected and/or known icing conditions, in proximity of
storms or in turbulence is forbidden.
Additional equipment can be required to fulfil national or specif-
ic operational requirements. The owner is responsible for ful-
filling these requirements.
Equipment list is addressed in Section 6.
20. FUEL
2 TANKS: 100 litres each one (26,42 US gallons)
MAXIMUM CAPACITY: 200 litres (52,8 US gallons)
MAXIMUM USABLE FUEL: 194.4 litres (51,35 US gallons)
APPROVED FUEL: MOGAS ASTM D4814
MOGAS EN 228 Super/Super plus (min. RON 95)
AVGAS 100 LL (ASTM D910)
Prolonged use of Aviation Fuel Avgas 100LL results in
greater wear of valve seats and greater combustion deposits
inside cylinders due to higher lead content. It is therefore
suggested to avoid using this type of fuel unless strictly nec-
essary. Make reference to Rotax Maintenance Manual which
prescribes dedicated checks due to the prolonged use of
Avgas.