EasyManua.ls Logo

Tecnam P92 Echo MKII - Page 31

Tecnam P92 Echo MKII
162 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 2- 9
POWERPLANT INSTRUMENTS
MARKINGS
10. POWERPLANT INSTRUMENTS MARKINGS
Powerplant instrument markings and their colour code significance are shown be-
low:
INSTRUMENT
RED RANGE
Minimum
limit
GREEN RANGE
Normal
operating
YELLOW
RANGE
Caution
RED RANGE
Maximum
limit
Propeller
RPM
----
580 - 2265
2265 - 2388
>2388
Engine
RPM
----
1410- 5500
5500-5800
>5800
Oil temp.
°C
<50
90 - 110
50 - 90
110 - 130
>130
CT
°C
---
0 - 120
---
>120
CHT
(1)
°C
---
0 - 135
---
>135
Oil pressure
bar
<0.8
2 - 5
0.8 - 2
5 - 7
(2)
7
Fuel press.
psi
<2.2
2.2-5.8 or 7.26
(3)
----
5.8 or 7.26
(3)
bar
<0.15
0.15-0.4 or 0.5
(4)
----
0.4 or 0.5
(3)
Fuel Q.ty
litres
<0
(5)
----
----
----
11. OTHER INSTRUMENTS MARKINGS
INSTRUMENT
RED RANGE
Minimum limit
GREEN RANGE
Normal operating
YELLOW RANGE
Caution
RED RANGE
Maximum limit
Voltmeter
<10.5 Volt
12 - 14 Volt
----
----
1
- Applicable for Engines up to serial no. 494543 (included) and repaired engine which doesn’t change the cyl-
inder head n°3 with new one (part no. 413195)
2
- In event of cold starting operation, it is permitted a maximum oil pressure of 7 bar for a short period.
3
- when fuel pump part no. 893110, 893114 and 893115 is installed
4
- when fuel pump part no. 893110, 893114 and 893115 is installed
5
- “0” indication shows the unusable fuel quantity (1.55 litres)
Section 2 - Limitations
1
st
Edition - Rev. 0

Related product manuals