Do you have a question about the Tecnoware EVO DSP PLUS TT 10 KVA and is the answer not in the manual?
Illustrates the internal structure and connections of the UPS system.
Explains the UPS behavior when connected to utility power but not actively supplying load.
Describes the UPS function during a power failure, using battery power.
Details the energy-saving ECO mode operation.
Outlines the procedure for maintenance bypass for servicing the UPS.
Introduces the front panel control interface, including the LCD and buttons.
Details the initialization process and the initial display on the LCD.
Details how to activate or deactivate audible alarms on the UPS.
Explains the procedure to remove a UPS from a parallel system.
Covers basic system information and language settings within the UPS.
Details the basic information available on the UPS, like firmware versions and serial numbers.
Explains where to find detailed operational parameter ranges and settings.
Identifies the location of breakers, terminal blocks, and communication interfaces on the UPS.
Describes the RS232 and USB ports for UPS management software.
Guides on installing the optional SNMP interface for network monitoring.
Explains the function and connection of the Emergency Power OFF connector.
Step-by-step guide for safely powering on the UPS for the first time.
Instructions for turning the UPS on when it is in Bypass mode.
Procedure for starting the UPS when no AC input power is available.
Steps to turn off the UPS when it is running on battery power without AC input.
Explains how the UPS manages load and handles overload situations.
Describes how to perform a battery status check through the control panel.
Details the wiring requirements for connecting UPS units in a parallel system.
Provides instructions and safety precautions for cleaning the UPS unit.
Covers battery maintenance, charging, and environmental considerations for longevity.
| Power Rating | 10 kVA |
|---|---|
| Active Power | 9 kW |
| Output Voltage THD | < 3% |
| Frequency | 50/60 Hz |
| Efficiency on Battery | > 90% |
| Output Waveform | Pure Sine Wave |
| Battery Type | Sealed Lead Acid (SLA) |
| Communication Interface | RS232, USB, SNMP (optional) |
| Operating Temperature | 0°C to 40°C |
| Storage Temperature | -15°C to 50°C |
| Topology | Double Conversion Online |
| Battery Voltage | 240 VDC |
| Communication Port | RS232, USB |
| Cooling | Forced air cooling |
| Overload Capacity | 125% for 10 minutes, 150% for 1 minute |
| Relative Humidity | 0 - 95% (non-condensing) |
| Efficiency | >90% |
| Protection | Overload, short circuit, over temperature |
| Nominal Input Voltage | 230 V (Single Phase) |
| Output Voltage | 230 V (Single Phase) |