DANGER
When the machine is disconnected from the air supply system, the devices marked with the
warning sign shown above may remain pressurised.
- The lter+regulator+lubricator is equipped with a semiautomatic condensation drain device. This
device operates automatically whenever the compressed air supply to the machine is cut off. Drain
the condensation manually (push-button d, g 23 ) when the level exceeds the mark X, g. 23.
- Check daily the correct tightening of the hexagonal screw (Fig. 22).
- Clean the top plate of the turntable every week: remove any accumulated dirt and clean with
environmentally-friendly solvents.
- Monthly checks:
• Clean the arms of the tool-carrying head, the bead breaking unit and the relative travel screws
with environmentally-friendly solvents only. Lubricate.
• Check the oil level in the air lubricator (g. 23) and, if necessary, top up with non-detergent
SAE20 oil to the indicated level Z.
• Clean with a dry cloth. Avoid contact with solvents.
• Check the oil ow-rate through the transparent cover K (correct ow-rate: 1 drop of oil every
4 bead breaking cycles). Adjust if necessary by turning the set screw Y g. 23.
23
a
b
c
e
d
x