2.2. Functionality of the system
The filter unit serves to suck off and filter polluted air (according to the intended use). First of all, the
coarse particles are separated at the prefilter mat in the filter section of the unit. The subsequent particle
filter cleans even fine smokes and dusts. The activated carbon filter absorbs gases and unpleasant
odours. An automatic filter monitoring indicates when a cleaning or a replacement of the filters is
necessary. The purified air is led back into the working room.
2.3. Intended use
The device is intended for commercial use. If the device is made publicly accessible, it must never be
operated unsupervised by authorized personnel, authorized by the operator.
The filter unit is intended for extraction and filtration of fumes that result from lasers or soldering jobs.
Improper use can damage parts and be a danger to life and limb!
The device must not be used for the extraction of oil-laden welding fume, explosive dust
and gases, hybrid mixtures, glowing or burning substances, gases, water, etc. The
device must not be operated in explosive zones.
Dangers arising from fire.
If the sucked medium is combustible fume or dust, the operator must determine
beforehand which fire protection measures are to be taken.