Questions and Answers

  • E
    Ethan GarciaAug 8, 2025
    Why is the cooling (heating) efficiency not good in my Tekno Point DKV Air Conditioner?
    • B
      Bryan HallAug 8, 2025
      If your Tekno Point Air Conditioner's cooling or heating efficiency isn't up to par, check the following: * Ensure the set temperature is appropriate. * Make sure the air inlet or outlet isn't blocked. * Check if the air filters are dirty. * Confirm that windows and doors are closed. * Verify the indoor fan speed isn't set too low. * Identify and eliminate any other heat sources in the room.
  • C
    Christina HernandezAug 11, 2025
    How to fix a Tekno Point Air Conditioner remote control that is not working?
    • G
      georgeleeAug 11, 2025
      If your Tekno Point Air Conditioner's remote control isn't working, try these steps: * If the air conditioner is disturbed or changing functions frequently, remove the power plug and reinsert it. * Ensure the remote control is within effective distance of the indoor unit. * Check for obstructions between the remote and the signal receptor. * Replace the remote's batteries if they're weak.
  • J
    Jeffrey DavenportAug 16, 2025
    Why is my Tekno Point DKV Air Conditioner indoor unit not delivering air?
    • A
      Amanda HughesAug 16, 2025
      The Tekno Point Air Conditioner indoor unit might not deliver air under certain conditions: * In HEAT mode, it prevents cool air when the indoor heat exchanger temperature is very low. * In HEAT mode with low outdoor temperature or high humidity, the unit defrosts automatically, stopping air delivery for 8-10 minutes. * In dehumidifying mode, the fan may stop to prevent condensed water from vaporizing again and to limit temperature increase.
  • N
    noah74Aug 20, 2025
    Why does my Tekno Point Air Conditioner have an unusual smell after starting?
    • J
      joycebuchananAug 20, 2025
      The unusual smell blowing from the outlet of your Tekno Point Air Conditioner after starting operation is caused by odors from the room that have been drawn into the air conditioner.
  • D
    dberryAug 25, 2025
    Why is there moisture on the air outlet vent of my Tekno Point DKV Air Conditioner?
    • M
      maciasjamesAug 25, 2025
      Moisture on the air outlet vent of your Tekno Point Air Conditioner indicates that the unit is running in high humidity for a prolonged period, causing condensation on the air outlet grill.
  • A
    Anne GoodAug 28, 2025
    What causes the creaking noise when I start or stop my Tekno Point DKV?
    • J
      Jessica GibsonAug 28, 2025
      The creaking noise you hear when starting or stopping your Tekno Point Air Conditioner is due to the deformation of plastic caused by temperature changes.
  • H
    heather50Sep 2, 2025
    What causes the noise from the indoor unit of my Tekno Point DKV Air Conditioner?
    • J
      james55Sep 2, 2025
      The noise from the indoor unit of your Tekno Point Air Conditioner can be caused by: * The sound of the fan or compressor relay switching on or off. * Sounds during defrosting or when stopping, due to refrigerant flow.

Tekno Point DKV Series Specifications

General IconGeneral
RefrigerantR410A
Power Supply220-240V, 50Hz
TypeSplit Type
Cooling Capacity9000 BTU/h
Weight8 kg