Operating
Instructions-FG
504
(SN
Β
040000
&
UP)
Output
Connections
The output
of
the
F
G
504
is
d
esigned
to
operate
as
α
50
Ω
voltage
source
working
into
α
50
Ω
load
.
At
h
igher
frequencies,
an
unterminated
or
improperly terminated
output
will
cause
excessive
aberrations
on
the output
waveform
(see
Impe
d
ance
M
atching d
iscussion)
.
L
oads
less
than 50
Ω
will
re
d
uce
the
waveform
amplitude
.
E
xcessive
distortion
or
aberrations,
due
to
improper
termination,
are
less
noticeable
at
the
lower
frequencies
(especially
with
sine
and
triangle
waveforms)
.
To
ensure
waveform
p
urity,
observe
the
following
precautions
:
1
.
U
se
good
quality
50
Ω
coaxial
cables
and
connec-
tors
.
2
.
M
ake
all
connections
tight
and
as
short
as
possible
.
3
.
Use
good
q
uality
attenuators
if it
is
necessary
to
reduce
waveform
am
p
litude
applied
to
sensitive
circuits
.
4
.
Use
terminations
or
impe
d
ance-matching
devices
to
avoid
reflections
when
using long cable
(6
feet
or
more)
.
5
.
E
nsure
that
attenuators,
terminations,
etc
.,
h
ave
adequate
p
ower
h
andling
capabilities
for
the output
waveform
.
If
there
is
α do
voltage
across the
output
loa
d
,
use
α
coupling
capacitor
in
series with
t
he
load
.
The
time
constant
of
the coupling
capacitor
and
load
mustbe
long
enough
to
maintain
p
ulse flatness
.
If
t
he
F
G
504
is
used
in
ear
ly
mo
d
els
of
t
h
e
TM
500
Series
P
ower
M
o
d
ules,
ripple
on
t
he
out
p
ut
wave-
form
can
be
excessive
in
some
cases
.
Th
e
ripple
r
esults
from
P
ower
M
odule
transformer
p
hasing
t
hat
is
incompatible
with
F
G
504
operation
;
however,
t
he
p
r
oblem
is
easily
cured
.
R
efer to
qualified
service
personnel
for
checking
transformer
p
h
asing
.
O
PER
ATI
N
G
CO
N
SID
ER
ATIO
N
S
English
2-2
NO
ΤΕ
CONTROLS
AND
CONNECTORS
FREQUENCY
(Hz)
:
Selects
frequency
of
opera-
tion,
or
lowest
frequency
in
sweep
mode
.
STOP
FREQUENCY
(Hz)
:
Selects
h
ighest
frequen-
cy
in
sweep
mode
.
FRED
=10
:
L
am
p
indicates
when
SYMMETRY
k
nob
is
p
ulle
d
out
.
RUN
:
(Button
out)
for
normal
operation
.
H
OLD
:
(Button
in)
Disables
the
generator
and
provides
an
output
do
level
equal
to
the
level
of
the
signal
when
t
he
button
was
p
ushed
.
(5
lower
frequency
ranges
only
.)
V
CF
INPUT
:
E
xternally
applied
voltage
varies
output
frequency
.
FREQUENCY
VERNIER
:
F
or
fine
frequency
variations
.
MULTIPLIER
:Determines
range
of
FREQUENCY
d
ial
.
ί
~
AM
INPUT
:
E
xternally
applied
signal
mo
d
ulates
sine
wave
output
.
9
Ο
L
ATCH
:
Pull
to
remove
the
p
lug-in
.
INPUT
:
A
pply
external
gating,
triggering,
or
phase-
locking
signals
to
this
connector
.
MAN
:
P
rovides
α
manual
trigger
in
TRIG
operation
or
manual
gate
in
GATE
o
peration
to
control
the
output
waveform
.
LEVEL
:
Selects
the
beginning
voltage
level
on
INPUT
waveform
for
triggered,
gated
,
or
phase-
locked
operation
.
Φ
L
OCK
:
B
utton
in
locks
output
waveform
frequen-
cy
to signal
applied
to
INPUT
connector
.
GATE
:
B
utton
in
causes
generator
to
produce
α
waveform
during
α
h
igh
level
at
the
INPUT
connec-
tor
.
T
RIG
:
B
utton
in
causes
generator
to
produce
one
cycle
of
output
waveform
for
each
positive-going
INPUT
signal
.
16
FREE
RUN
:
B
utton
in
causes
continuous
output
waveform
.
REV
ΜΑΥ
1981

Questions and Answers: