EasyManua.ls Logo

Tektronix FG 504

Tektronix FG 504
178 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LEVEL
control
M
i
d
range
S
WEEP
pus
hb
utto
ns
FREE
RUN
W
aves
h
a
pe
pus
h
butto
n
s
Sq
uare
wave
O
FF
SET
cont
r
ol
M
idra
n
ge
PH
AS
E
co
n
trol
M
i
d
range
S
WEEP
D
UR
ATIO
N
switc
h
0
.1
ms
V
A
R
iable
Fu
lly
ccw
R
IS
E
an
d F
A
LL
TIME
switc
h
F
IX
E
D
V
A
R
iable
F
ully
ccw
ATTENU
ATO
R
(d
B
)
O
dB
V
A
R
iable
F
ully
cw
T
R
IG
LEVEL
M
i
d
ra
n
ge
SY
MME
TRY
M
idra
n
ge
b
.
Connect
an
unterminated
coaxial
cable
from
t
h
eL
I
N
S
WEEP
O
U
T
PU
T
j
ac
k
to
t
h
e
oscillosco
pe
vertical
input
.
V
erify
t
h
at
t
he outp
ut
sig
n
al
varies
from
0V
to
10
V
f5°/
ο
from
100
seco
nds
to
1
ms
and
±10
ο
/ο
from
1
ms
to
0
.1
ms
.
c
.
Pr
ess
t
he
TR
IG
S
WP
b
utto
n
i
n
.
C
heck
for
on
e
swee
p
eac
h time
t
he
MAN
button
is
pressed
.
Connect
α 100
Hz
si
n
e
wave
sig
n
al
from
t
h
e
fu
n
ctio
n
ge
n
erator
to
t
h
e
S
WEEP
TR
IG
I
NPU
T
j
ack
an
d a
dj
ust
t
h
e
outp
ut
sig
n
al
to
1
V
ρ
-
p
.
V
erify
t
h
at
t
he F
G
504
swee
p
ge
n
erator
can
be
triggered
on
t
h
is
waveform
by
ad
j
usting
t
he
TR
IG
LEVEL
kn
ob
.
6
.
Output
Amplitude,
F
lat
n
ess,
Offset,
and
Attenuato
r
Accuracy
α
.
Set
t
h
e
F
G
504
co
n
trols
as
follows
:
Calibration
P
roced
u
re-
F
G
504
(S
NΒ
040000
&
UP)
P
e
r
forma
nce
C
h
ec
k
ATTENU
ATO
R
(dB)
0
VA
R
ia
b
le
F
ully
cw
T
R
IG
LEVEL
M
idra
n
ge
SY
MME
T
R
Y
M
i
d
ra
n
ge
b
.
Co
nn
ect
t
he output
of
t
he F
G
504
to
t
he
do
cou
p
led
vertical
i
np
ut
of
t
he
oscillosco
p
e
t
h
ro
ug
h
α 50
Ω
unter-
minate
d
cable
.
C
heck
t
h
at
t
heoutput
is at
least
30
Vρ
-
ρ
on
all
MUL
TI
PL
I
ER
ranges
.
V
erify
t
h
at
t
h
e
ATT
ENU
ATO
R
V
A
R
iable
co
n
t
r
ol
will
r
e
d
uce
t
he out
p
ut
to
3
.0
V
ρ
-
p
.
R
et
u
r
n
t
he
VA
R
iable
co n
trol
to
fully
cw
.
Con
n
ect
α
50
Ω
termination
at
t
h
e
scope
end
of
t
h
e
50
Ω
out
p
ut
cable
.
V
erify
t
h
at
t
h
eoutput
am
p
lit
ud
e
varies
less
t
h
an
±6
ο
/ο
on
all
ranges
for
all
t
h
ree
wave
s
h
apes
.
V
erify
t
h
at
t
he
output
am
p
lit
u
de
varies
less
t
han
±11
ο
/
ο
from
40
kH
z
to
40
MHz
(±1
d
B)
.
V
erify
t
h
at
t
he
t
h
ree
wave
s
h
apes
h
ave
t
h
e
same
amplitu
d
es,
±0
.5
d
B
at
10
kH
z
.
Set
t
h
e
ATTENU
ATO
R
to
eac
h
step
an
d
verify
t
h
at
t
h
e
accuracy
at
eac
h
ste
p
is
wit
h
i
n
±0
.5
dB
p
er
d
ecade
.
R
emove
t
he
550
Ω
termi
n
a-
tio
n
.
W
it
h the
ATTENU
ATO
R
at
-50
d
B, pull
out
t
h
e
O
FF
SET
co
n
trol
an
d
vary
it
from
one
end
of
rotation
tot
he
ot
h
er
.
V
erify
t
h
at
t
he output ch
a
n
ges
from
+7
.5
V
to
-7
.5
V
wit
h the out
p
ut
unterminated
.
7
.
Out
p
ut
W
aveforms
(Tria
n
gle
Symmet
r
y,
Sine
W
ave
Distortion
,
Sq
uare
W
ave
Rise
and
F
all
Time)
α
.
Set
t
he
F
G
504
con
trols
as
follows
:
b
.
Set
t
he
oscilloscope
controls
to
display
two
cycles
of
t
he
waveform
across
t
he
graticule
.
U
sing
t
he
delayed
45
H
O
LD/
RUN
p
ush
b
u
tto
n
RUN
FRE
Q
UEN
CY
Hz
(STA
R
T)
dial
10
STO
P
d
ial
40
MUL
TI
PL
I
ER
10
5
FRE
Q
UEN
CY
VERN
I
ER
(V
A
R)
F
ully
cw
T
R
IGG
ER
/
FREE
RUN
pus
h
button
FREE
RUN
LEVEL
co
n
trol
M
idrange
S
WEEP
pus
hb
utto
ns
Out
W
aveshap
e
pus
h
buttons
Square
W
ave
O
FF
SET
con
trol
M
idrange
PH
AS
E
control
M
i
d
ra
n
ge
S
WEEP
D
UR
ATIO
N
switc
h
O
FF
V
A
R
iable
F
ully
ccw
R
IS
E
an
d F
A
LL
TIME
switc
h F
IX
E
D
V
A
R
iable
F
ully
ccw
H
O
LD/
RUN
push
butto
n
RUN
FRE
Q
UEN
CY
Hz
(STA
R
T)
dial
10
STO
Pd
ial
40
MUL
TI
PL
I
ER
10"
FRE
Q
UEN
CY
VERN
I
ER
(V
A
R)
F
ully
cw
T
R
IGG
ER
/
FREE
RUN
pushbutton
FREE
RUN
LEVEL
control
M
i
d
range
S
WEEP
pus
h
b
u
ttons
Out
W
avesh
ape
pus
h
butto
ns
Triangle
In
O
FF
SET
con
trol
M
idra
n
ge
PH
AS
E
co
n
trol
M
idrange
S
WEEP
D
UR
ATIO
N
switc
h
O
FF
VA
R
iable
F
ully
cw
R
IS
E
a
n
d
F
A
LL
TIME
switc
h
F
IX
E
D
VA
R
iable
F
ully
ccw
ATT
ENUATO
R
(dB)
O
dB
VA
R
iable
F
ully
cw
T
R
IG
LEVEL
M
i
d
ra
nge
SY
MME
TR
Y
M
i
d
range

Related product manuals