Commands Listed in Alphabetical Order
TRIGger:A:BU
S:B<x>:SPI:CONDition
Sets or returns the trigger condition for a SPI trigger. Applies t o bus <x>, where x
is the bus number.
Conditions
This command requires a DPO2EMBD application module.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:SPI:CON Dition
{SS|STARTofframe|MISO|MOSI |MISOMOSI}
TRIGger:A:BUS:B<x>:SPI:CON Dition?
Arguments
SS species the Slave Selection condition.
STARTofframe species the start of frame condition.
MISO species the Master-In Slave-Out condition.
MOSI species the Master-Out Slave-In condition.
MISOMOSI species the Master-In Slave-Out and Master-Out Slave-In conditions.
TRIGger:A:BUS:B<x>:SPI:DATa{:IN|:MISO}:VALue
Sets or returns the binary data string to be used for a SPI trigger if the trigger
condition is MISO or MISOMOSI. Applies to bus <x>, where x is the bus number.
Conditions
This command requires a DPO2EMBD application module.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:SPI:DAT a{:IN|:MISO}:VALue <QStri ng>
TRIGger:A:BUS:B<x>:SPI:DAT a{:IN|:MI
SO}:VALue?
Arguments
<QString> is the binary data string, where the number of bits is 8 times the
number of bytes specied. The only allowed characters in the string are 0, 1,
and X.
MSO2000B, DPO2000B, MSO2000 and DPO2000 Series Oscilloscopes Programmer Manual 2-311