Commands Listed in Alphabetical Order
MEASUREMENT:M
EAS1:STATE?
might return : MEASUREMENT:MEA S1:STATE 0
indicating that measurement defined for measurement slot 1 is disabled.
MEASUrement:MEAS<x>:STDdev? (Query Only)
Returns the standard deviation of values accumulated for this measurement since
the last statistical reset. Measurements are specified by <x>, the measurement
slots, from 1 through 4.
Group
Measurement
Syntax
MEASUrement:MEAS<x>:STDdev ?
Examples
MEASUREMENT:MEAS1:STDDEV? might return :MEASU REMENT:MEAS1:STDDEV
21.0E-12.
MEASUrement:MEAS<x>:TYPe
Sets or returns the measurement type defined for the specified measurement slot.
The measurement slot is specified by <x>, which ranges from 1 through 4.
Group
Measurement
Syntax
MEASUrement:MEAS<x>:TYPe
{AMPlitude|AREa|BURst|CARe a|CMEan|CRMs|DELay|FALL|FREQuency
|HIGH|LOW|MAXimum|MEAN|MIN Imum|NDUty|NEDGECount|NOVershoot
|NPULSECount|NWIdth|PDUty| PEDGECount|PERIod|PHAse|PK2Pk
|POVershoot|PPULSECount|PW Idth|RISe|RMS}
MEASUrement:MEAS<x>:TYPe?
Arguments
AMPlitude measures the amplitude of the selected waveform. In other words, it
measures the high value less the low value measured over the entire wa veform or
gated region. This measurement is available only on DPO models.
Amplitude = High – Low
AREa measures the voltage over time. The area is over the entire waveform or
gated region and is measured in volt-seconds. The area measured above the
ground is positive, while the area below ground is negative. This measurement is
available only o n DPO models.
BURst measures the duration of a burst. The measurement is made over the entire
waveform or gated region.
MSO2000B, DPO2000B, MSO2000 and DPO2000 Series Oscilloscopes Programmer Manual 2-203