EasyManuals Logo
Home>Tektronix>Test Equipment>MSO2012B

Tektronix MSO2012B Programmer's Manual

Tektronix MSO2012B
441 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #333 background imageLoading...
Page #333 background image
Commands Listed in Alphabetical Order
Examples
TRIGGER:A:LEV
EL:AUXIN E CL
sets the auxiliary input trigger level to -1.3
volts.
TRIGGER:A:LE
VEL:AUXIN?
might return TRIGGER:A:LEVEL:AUXIN 0.0E+0
indicating that the auxiliary input trigger level is 0.0 volts.
TRIGger:A:LEVel:CH<x>
Sets or returns the trigger level for the specied channel. Each channel can have
an independent level.
Group
Trigger
Syntax
TRIGger:A:LEVel:CH<x> {<NR3>|TTL|EC L}
TRIGger:A:LEVel:CH<x>?
Arguments
<NR3> species the trigger level in user units (usually volts).
TTL species a preset TTL high level of 1.4 V.
ECL species a preset ECL high level of –1.3 V.
Examples
TRIGGER:A:LEVEL:CH2? might return :TRIGGER:A:LEVEL:CH2
1.3000E+00
indicating that the A edge trigger is set to 1.3 V for channel 2.
TRIGGER:A:LEVEL:CH3 TTL sets the A edge trigger to TTL high level for
channel 3.
TRIGger:A:LEVel:D<x>
Sets or returns the trigger level for the specied digital channel <x>, where x is
the channel number. The digital channels do not have independent trigger levels.
Channels D0–D7 share one common trigger level and D8–D15 share another
common trigger level. For example: Changing the trigger level for D3 changes
the levels for D0–D7.
Group
Trigger
Syntax
TRIGger:A:LEVel:D<x> {<NR3>|ECL|TTL }
TRIGger:A:LEVel:D<x>?
MSO2000B, DPO2000B, MSO2000 and DPO2000 Series Oscilloscopes Programmer Manual 2-317

Other manuals for Tektronix MSO2012B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MSO2012B and is the answer not in the manual?

Tektronix MSO2012B Specifications

General IconGeneral
BrandTektronix
ModelMSO2012B
CategoryTest Equipment
LanguageEnglish

Related product manuals