Commands Listed in Alphabetical Order
SEARCH:SEARC
H<x>:TRIGger:A:SETHold:THReshold:REF<x>
Sets or returns the trigger search setup and hold lower threshold to determine
where to place a mark. Search<x> is the search number, which is a l ways 1.
REF<x> is the
reference waveform number.
Conditions
MSO oscilloscopes o nly.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A :SETHold:THReshold:REF<x> <NR3>
SEARCH:SEARCH<x>:TRIGger:A :SETHold:THReshold:REF<x>?
Arguments
<NR3> is the lower threshold in volts.
SEARCH:SEARCH<x>:TRIGger:A{:TRANsition|:RISEFall}:DELTatime
Sets or returns the transition time setting for an transition trigger search to
determine where to place a mark.<x> is the search number.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A {:TRANsition|:RISEFall}:DELTatime
<NR3>
SEARCH:SEARCH<x>:TRIGger:A {:TRANsition|:RISEFall}:DELTatime?
Arguments
<NR3> speci es the transition time, in seconds.
SEARCH:SEARCH<x>:TRIGger:A{:TRANsition|:RISEFall}:POLarity
Sets or returns the polarity setting for an transition trigger search to determine
where to place a mark. <x> is the search number.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A {:TRANsition|:RISEFall}:POLarity
{EITher|NEGative|POSitive}
SEARCH:SEARCH<x>:TRIGger:A {:TRANsition|:RISEFall}:POLarity?
MSO2000B, DPO2000B, MSO2000 and DPO2000 Series Oscilloscopes Programmer Manual 2-281

Other manuals for Tektronix MSO2024

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MSO2024 and is the answer not in the manual?

Tektronix MSO2024 Specifications

General IconGeneral
BrandTektronix
ModelMSO2024
CategoryTest Equipment
LanguageEnglish

Related product manuals