EasyManuals Logo
Home>Tektronix>Test Equipment>MSO2024

Tektronix MSO2024 Programmer's Manual

Tektronix MSO2024
441 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #337 background imageLoading...
Page #337 background image
Commands Listed in Alphabetical Order
Syntax
TRIGger:A:LOG
Ic:INPut:CLOCk:EDGE {FALL|RISe|EITher}
TRIGger:A:LOGIc:INPut:CLOC k:EDGE?
Arguments
RISe species to trigger on the rising or positive edge of a signal.
FALL species to trigger on the falling or negative edge of a signal.
EITher species to trigger either on the falling or rising edge of a signal.
TRIGger:A:LOGIc:INPut:CLOCk:SOUrce
Sets or returns the channel to use as the clock source. The clock can be selected as
NONE. A selection of None implies pattern trigger. Any other selection implies
state trigger.
Group
Trigger
Syntax
TRIGger:A:LOGIc:INPut:CLOC k:SOUrce {CH1|CH2|CH3|CH4 |
D0|D1|D2|D3|D4|D5|D6|D7|D8 |D9|D10|D11|D12|D13|D14|D15|NONE}
TRIGger:A:LOGIc:INPut:CLOC k:SOUrce?
Arguments
CH1–CH4 species the analog input channel source.
D0–D15 species the digital input c hannel source.
NONE species a Pattern trigger.
TRIGger:A:LOGIc:INPut:D<x>
Sets or returns the logic pattern for a trigger on digital channel <x>, where x
is t
he channel number.
Group
Trigger
Syntax
TRIGger:A:LOGIc:INPut:D<x> {HIGH|LOW|X }
TRIGger:A:LOGIc:INPut:D<x> ?
Arguments
High species the logic high state.
Low species the logic low state.
X species a "don't car e" sta te.
MSO2000B, DPO2000B, MSO2000 and DPO2000 Series Oscilloscopes Programmer Manual 2-321

Other manuals for Tektronix MSO2024

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MSO2024 and is the answer not in the manual?

Tektronix MSO2024 Specifications

General IconGeneral
BrandTektronix
ModelMSO2024
CategoryTest Equipment
LanguageEnglish

Related product manuals