EasyManuals Logo
Home>Tektronix>Test Equipment>MSO2024B

Tektronix MSO2024B Programmer's Manual

Tektronix MSO2024B
441 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #254 background imageLoading...
Page #254 background image
Commands Listed in Alphabetical Order
SAVe:WAVEfor
m(NoQueryForm)
This command saves a specied waveform or all displayed waveforms (excluding
serial bus waveforms). Only individual analog waveforms (CH<x>, MATH and
REF<x>) can b
e saved to reference memory locations.
You can save all displayed waveforms, excluding serial bus w aveforms, to a
single CSV
le when the
SAVE:WAVEFORM:FILEFORMAT is set to SPREADSHEET.
You can save all displayed waveforms, excluding serial bus
waveforms
to consecutive ISF (internal save format) les when the
SAVE:WAVEFORM:FILEFORMAT is set to INTERNAL.
NOTE. For MSO models, reduced resolution waveform data is not available for
the digital channels.
Group
Save and Recall
Syntax
SAVe:WAVEf
orm[<wfm>,{REF<x>}] | [<wfm>, <QString>] | [ALL,
<QString>]
Related Commands
RECAll:WAVEform, SAVe:WAVEform:FILEFormat
Arguments
<wfm>, <REF<x>> saves the specied waveform to the specied reference
memory location. <wfm> can be any live analog channel (where <x> is the
channel number), the MATH1 waveform, or another refer ence waveform (such
as REF1).
<wfm>, <QString> saves the specied waveform to the le specied in the
quoted string argument. Any live channel (such as CH1), the MATH1 waveform,
any reference waveform can be saved to a le.
ALL, <Q String> saves all displayed waveforms, excluding serial bus
waveforms, to a single CSV le specied by the quoted string argument when the
SAVE:WAVEFORM:FILEFORMAT is set to SPREADS HEET, or saves all displayed
waveforms, excluding serial bus waveforms to individual ISF (internal save
format) les with a le name prexspecied by the argument with an underscore
(_) and the waveform ID (such as CH1, REF1, MATH) appended to the le
name(s).
Examples
SAVE:WAVEFORM CH1,REF1 saves the CH1 waveform in reference memory
location 1.
2-238 MSO2000B, DPO2000B, M SO2000 and DPO2000 Series Oscilloscopes Programmer Manual

Other manuals for Tektronix MSO2024B