Commands Listed in Alphabetical Order
SEARCH:SEARC
H<x>:TRIGger:A:BUS:B<x>:CAN:FRAMEtype
Sets or returns the CAN Frame Type to be used if the trigger search condition is
Frame Type.
SEARCH<x> is the search number a nd B<x> is the bus number.
Conditions
This command requires a DPO2AUTO application m odule.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger: A:BUS:B<x>:CAN:FRAMEtype
{DATA|REMote|ERRor|OVERLo ad}
SEARCH:SEARCH<x>:TRIGger: A:BUS:B<x>:CAN:FRAMEtype?
Arguments
DATA specifiesadataframe.
REMote specifies a remote frame.
ERRor specifies an error frame.
OVERLoad specifies an overload frame.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:CAN{:IDentifier|:ADDRess}:MODe
Sets or returns the CAN addressing mode for a trigger search to a standard or
extended format.
SEARCH<x> is the search number and B<x> is the bus number.
Conditions
This command requires a DPO2AUTO application m odule.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger: A:BUS:B<x>:CAN{:IDentifier|:
ADDRess}:MODe {STandard|EXTended}
SEARCH:SEARCH<x>:TRIGger: A:BUS:B<x>:CAN{:IDentifier|:
ADDRess}:MODe?
Arguments
STandard specifies an 11-bit identifier field.
EXTended specifies a 29-bit identifier field.
2-250 MSO2000B, DPO2000B, M SO2000 and DPO2000 Series Oscilloscopes Programmer Manual