Teledyne Lecroy HDO4104A User Manual

Teledyne Lecroy HDO4104A
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Operator's
Manual
HDO4000
High Definition Oscilloscopes
www.calcert.com sales@calcert.com1.888.610.7664
0
5
10
15
20
25
30

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Teledyne Lecroy HDO4104A and is the answer not in the manual?

Teledyne Lecroy HDO4104A Specifications

General IconGeneral
Bandwidth1 GHz
Channels4
Form FactorBenchtop
Vertical Resolution12-bit
Display TypeLCD
Input CouplingAC, DC, GND
Display12.1 inch
Input Impedance1 MΩ ± 1% in parallel with 16 pF ± 2 pF; 50 Ω ± 1%
Operating Temperature0°C to +40°C

Summary

Welcome and Introduction

Safety Information

Precautions relating to power and cooling.

Manual Structure

Sections covering oscilloscope operation and care.

Software Options

Documentation availability on the website.

Safety Instructions

Symbols

Alerts for potential instrument and safety hazards.

Precautions

Guidelines for safe operation and handling.

Start Up Procedures

Setting Up the Oscilloscope

Checking shipment, carrying, and placement.

Positioning the Feet

Adjusting viewing angles for the instrument.

Powering On/Off and Software Activation

Powering On/Off

Using the standby button and proper shutdown.

Software Activation

Firmware updates and option licensing.

Inputs and Outputs Overview

Front Panel I/O

Power, BNC, USB, Mixed Signal ports.

Side Panel I/O

Video, Ethernet, Audio ports.

Input and Output Connections

Back Panel I/O

Aux Out, Ref In/Out, USBTMC, AC Power.

Analog Inputs

BNC connectors and ProBus interface.

Probes

Compatibility and specifications.

Understanding the Interface

Touch Screen

Primary control and display interface.

Menu Bar

Main navigation for oscilloscope functions.

Signal Display Grid

Area displaying waveform traces and divisions.

Display Elements and Indicators

Descriptor Boxes

Summarizing settings and acting as navigation.

Channel Descriptor Box

Details for analog signal inputs.

Grid Indicators

Trigger position and delay markers on the display.

Front Panel Controls Overview

Shortcut Buttons

Quick access to common functions.

Knobs and Buttons

Turn/push actions for control.

Front Panel Controls - Trigger and Horizontal

Trigger Controls

Level, Auto, Normal, Single, Stop modes.

Horizontal Controls

Delay and Time/division adjustment.

Front Panel Controls - Vertical, Math, Cursors, Adjust

Vertical Controls

Channel, Offset, Gain, Dig button.

Math, Zoom, and Memory Buttons

Accessing trace functions.

Cursor Controls

Type and knob for cursor placement.

Adjust and Intensity Controls

Adjust knob and intensity settings.

Trace Management

Analog & Digital Traces

Turning traces on/off.

Activate Trace

Using trace descriptor boxes.

Zooming Waveforms

Create Zoom

Magnifying selected regions of a trace.

Zoom Controls and Management

Turn off Zoom

Methods to disable zoom traces.

Quick Zoom

Using the front panel zoom button.

Vertical Settings Configuration

Vertical Controls

Scale, offset, coupling, bandwidth.

Pre-Processing Controls

Noise filtering and interpolation.

Probe Dialog

Probe attributes and settings.

Deskew Channels

Deskew Procedure

Compensating for propagation delays.

Digital Signal Input

Digital Traces

Line and Bus display modes.

Activity Indicators

Status of digital lines.

Digital Group Setup

Digital Group Set Up

Configuring digital line groups.

Digital Display Set Up

Choosing display modes: Lines, Bus, Lines & Bus.

Timebase Settings

Sampling Modes

Real Time, Sequence, Roll, RIS.

Timebase Mode

Time/Division, Delay settings.

Trigger System Overview

Trigger Capabilities

Simple, Pattern, SMART Triggers.

Trigger Modes

Auto, Normal, Single, Stop.

Trigger Types

Basic Triggers

Edge, Width, Pattern, TV.

Smart Triggers

Interval, Glitch, Runt, SlewRate.

Trigger Settings Configuration

Type, Source, Coupling

Core trigger configuration.

Level and Find Level

Setting the trigger threshold.

Trigger Holdoff

Hold Off by Time

Waiting a duration before triggering.

Hold Off by Events

Counting events before triggering.

Display Setup Configuration

Grid Types

Auto, Single, XY, XYSingle.

Intensity and Line Styles

Adjusting grid and trace appearance.

XY Displays and Persistence

XY Displays

Plotting phase shift between signals.

Persistence Overview

Revealing signal anomalies over time.

Cursors for Measurement

Cursor Types

Standard and special cursor options.

Cursor Settings

Display and positioning cursors.

Measurement Tools

Measure Gate

Narrowing waveform span for analysis.

Set Up Measurement

Configuring custom parameters.

Standard Measurement Parameters

Parameter Descriptions

Amplitude, Area, Base, Delay, etc.

Advanced Measurement Views

View Histicon

Miniature histograms for statistical distribution.

View Trend

Plotting parameter measurements over time.

Math Functions

Single vs. Dual Operation Functions

Applying math operations.

Graphing

Plotting trends using the Trend button.

Setting Up Math Functions

Set Up Math Function

Creating single/dual operator traces.

Rescaling and Assigning Units

Set Up Rescaling

Applying multiplication factors and constants.

Enhanced Resolution Filtering

Set Up Enhanced Resolution

Applying ERes as pre-processing or math.

How the Instrument Enhances Resolution

Filters and bandwidth reduction.

FFT Analysis

Set Up FFT

Configuring output type and weighting windows.

Choosing a Window

Selecting spectral window types.

Analysis Tools Overview

Trends and Conditional Tests

Pass/Fail, WaveScan.

History Mode

Reviewing acquisition history.

WaveScan Search and Find

Scan Modes

Edge, Non-monotonic, Runt, Measurement modes.

WaveScan Modes Explained

EDGE MODE

Detecting signal edges.

NON-MONOTONIC MODE

Finding multi-threshold crossing events.

RUNT MODE

Identifying incomplete pulses.

WaveScan Setup and Pass/Fail Testing

Set Up WaveScan

Searching for events in acquisitions.

Pass/Fail Testing

Comparing signals against a mask.

Mask Creation and Loading

Make Mask

Creating a new mask from a waveform.

Load Mask

Recalling saved or industry standard masks.

History Mode Operation

To view history

Navigating and selecting acquisitions.

Utilities Overview

Utilities Settings

Instrument interaction and preferences.

Touch-Screen Calibration

Maintaining touch screen accuracy.

System Status and Remote Control

System Status

Instrument information display.

Remote Control Settings

Configuring TCPIP, LXI, USBTMC, GPIB.

Print (Hardcopy) Settings

Send to Printer

Adding and configuring printers.

Outputting Screen Captures

Print to File

Saving captures to a file.

Copy to Clipboard

Copying captures for pasting.

Send to E-Mail

Emailing capture files.

Calibration and Date/Time Settings

Calibration Settings

Manual calibration procedures.

Date/Time Settings

Configuring date and time.

Disk Utilities

Delete Files and Folders

Managing files on the instrument.

Create a New Folder

Organizing files.

Preferences Settings

Audible Feedback

Instrument audio output.

Automatic Calibration

Temperature dependent calibration.

Language Selection

Setting display language.

Performance Settings

Optimizing for analysis or display.

Save/Recall Overview

Save/Recall Setups

Storing and recalling panel configurations.

Saving Oscilloscope Setups

Methods for saving setups.

Saving Waveforms

SAVE WAVEFORM TO MEMORY

Saving traces to internal memory.

SAVE WAVEFORM TO FILE

Selecting data formats for saving.

AutoSave and Recall Waveform

AutoSave

Automatic waveform saving after trigger.

Recall Waveform

Retrieving saved waveforms.

LabNotebook Functionality

Create Notebook Entry

Capturing and documenting oscilloscope state.

LabNotebook Drawing Toolbar

Markup Tools

Pen, Circle, Arrow, Text for annotations.

Managing Notebook Entries

Select Notebook Entries

Choosing entries for management.

Filter Notebook Entries

Applying criteria to lists.

View Notebook Entries

Previewing entries before output.

Managing Notebooks

Create New Notebook

Organizing entries by project/user.

Back Up Notebook

Saving notebooks to external media.

Flashback Recall and Custom Reports

Flashback Recall

Recalling saved oscilloscope states.

Customize Report

Replacing default logo in reports.

Maintenance Procedures

Cleaning

Exterior cleaning instructions.

Calibration

Factory and manual calibration options.

Touch Screen Calibration

Maintaining touch screen accuracy.

Language Selection

Changing display and OS language.

Software Options and Firmware Updates

Add Software Option

Installing license keys.

X-Stream Firmware Update

Downloading and installing firmware.

System Recovery

Using Acronis True Image Home

Restoring operating system and application.

System Recovery Wizard

Run the Recovery Wizard

Steps for restoring using Acronis.

Reinstall the Oscilloscope Application

Installing the X-Stream DSO.

Technical Support

Phone Support

Contacting service centers.

Web Support

Submitting requests via website.

Certifications

EMC Compliance

Electromagnetic Compatibility declarations.

Safety and Compliance

Australia & New Zealand EMC

Compliance declarations.

Environmental Compliance and Warranty

Environmental Compliance

End-of-Life Handling, RoHS, ISO.

Warranty

Terms and conditions of product warranty.