Page 65 of 65
TVP Manual (full) March 2007 CE rev 03.doc
4.42 Operation temperatures and pressures
The following table gives the typical values, which maybe experienced during the operation of
a TVP. It is important to appreciate that the values are influenced strongly by the operational
mode and the amount of heat being pumped by the unit. The supply water temperature also
has a profound impact when the system is in standby for long periods or where it is operating
close to its maximum duty.
Caution
A system operating outside of its design parameters may be harbouring a quiescent system
malfunction.
Parameter Description Acceptable (normal) range
SP start up * Suction Pressure 20 to 120 psi
DP start up * Discharge pressure 100 to 420 psi
SP unit running 7 to 60 psi
SP & DP system off System balance pressure 235 to 260 psi
CT Coldest temperature -100 to –170
o
C
WT Water temperature 35
o
C default 20 - 40
o
C optional
CI Coil in temp +90
o
C to –150
o
C
CO Coil out temp +40
o
C to –150
o
C