EasyManuals Logo

Telit Wireless Solutions ME310G1 At Commands Reference Guide

Telit Wireless Solutions ME310G1
545 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #213 background imageLoading...
Page #213 background image
ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev.4 Page 213 of 545 2020-04-15
3.5.2. AT+CPMS - Preferred Message Storage
The command selects the memory storage used by SMs (Short Messages).
3GPP TS 27.005
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Required
Auto
No
-
2
AT+CPMS=<memr>[,<memw>[,<mems>]]
Set command selects memory storages <memr>, <memw> and <mems> to be used for reading,
writing, sending and storing SMs
The command returns the memory storage status in the format:
+CPMS: <usedr>,<totalr>,<usedw>,<totalw>,<useds>,<totals>
The returned parameters are described in the Additional info section.
Parameters:
Name
Type
Default
Description
<memr>
string
SE
memory from which messages are read and deleted
Values:
ME
:
SMS memory storage in Flash
SE
:
SIM SMS memory storage
<memw>
string
SM
memory to which writing and sending operations are made
Values:
ME
:
SMS memory storage in Flash
SM
:
SIM SMS memory storage
<mems>
string
SM
memory to which received SMs are preferred to be stored
Values:
ME
:
SMS memory storage in Flash
SM
:
SIM SMS memory storage
Additional info:
Here is the meaning of the parameters returned by the command.
Name
Type
Default
Description
<usedr>
integer
-
number of SMs stored in <memr>
<totalr>
integer
-
max number of SMs that <memr> can contain
<usedw>
integer
-
number of SMs stored in <memw>
<totalw>
integer
-
max number of SMs that <memw> can contain

Table of Contents

Other manuals for Telit Wireless Solutions ME310G1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions ME310G1 and is the answer not in the manual?

Telit Wireless Solutions ME310G1 Specifications

General IconGeneral
Module TypeLTE Cat M1/NB1
Operating Temperature-40°C to +85°C
Form FactorLGA
Storage Temperature-40°C to +85°C
RoHS ComplianceYes
Frequency BandsB1/B2/B3/B4/B5/B8/B12/B13/B20/B25/B26/B28/B66/B71
InterfaceUART, GPIO, I2C, SPI
Cellular TechnologyLTE Cat M1
SIM Interface1.8V/3V
CertificationsGCF, PTCRB, CE, FCC, IC