Electrical:
Each UP100J EV station oers one Level-2 standard coupler, and one Level-1 charging
Receptacle, therefore requiring one (1) dedicated 208-240VAC circuit, one (1) dedicated 110VAC circuit and a
shared earth/ground wire for a total of 5 wires running to the station.
Level-1 input/output voltage: 110 to 120VAC
Level-1 input service breaker: Dedicated 20 Amp single pole breaker (non-GFCI)
Level-1 max output current: 16 A
Level-1 output connector: NEMA 5-20 receptacle
Level-2 input/output voltage: 208 to 240VAC
Level-2 input service breaker: Dedicated 40 Amp double pole breaker (non-GFCI)
Level-2 max output current: 30 A
Level-2 output connector: SAE J1772TM connector with up to 25ft cable
Standby power consumed: < 10Watts continuous
Total max. output power from station: 7.2 kW
Networking:
LAN: Physically and digitally secure hard wired Cat 5 between master and slave stations
WAN: Cellular data network options are available for the master station.
Safety and operational:
Safety: ETL listed to UL2594 UL2231-1, UL2231-2, and UL991. Meets NEC Article 625/SAE J1772
Operating temperature: -30°F to +130°F (-35°C to +55°C )
Operating humidity: Up to 95% non-condensing
Enclosure rating: NEMA 3R
Terminal block temperature rating: 212°F (100°C)
Interface devices:
Screen: Heated full color transective LCD display, with auto brightness adjust for ambient light
RFID reader: Active multi-standard
Touch pad: Backlight numeric membrane type buttons
LED status indicators: RGB led with auto brightness adjust for ambient light
Safety devices:
Ground fault detection: 20mA Charge Circuit Interrupt Device (CCID20) including 3 auto retry (15 minute
delay between each auto retry)
Detection devices:
Level-2 plug-out detection: Power cuto per SAE J1772TM
Power metering: Utility grade meter in each charging port
Local grid health: Service line voltage and frequency detection and logging
Ambient light sensor: Automatically adjusts brightness of screen and indicator LEDs
Ambient temperature sensor: Controls heating of LCD display in extreme cold
Physical Strength:
Housing wall: 1/4” thick aluminum 6061 T6 (No additional protective bollards necessary)
Base for pad mount housing (UP_PMP) unit: 12”x12”x1/2” thick aluminum 6061 T6
End caps: Solid aluminum T6
Interface parts: Latest UV resistant polycarbonate technology
Hardware: All internal and external hardware is stainless steel
Vandal protection: Custom external security fasteners (stainless steel)
Available Housing Post Dimensions:
Pad Mount Post (UP_PMP): 7” cylinder with a height of 70” and base of 12”x12”x1/2” thick
Direct Burial Post (UP_DBP): 7” cylinder with a height of 102”
Wall/Pole Mount Post (UP_WMP): 7” cylinder with a height of 54”
Page 3
Specications:
KIT302-IM-20140501