The °C icon lights up
Allow the machine proper ventilation; when the thermal conditions have been recovered, normal operations are available again.
Reset the machine using the ON / OFF switch.
Long periods of inactivity can damage the cooling unit pump and cause problems
when starting up. First ensure the presence of liquid inside the tank and check the
placement to the right of the in / out pipes - as in the instructions below:
• disconnect the blue water outlet hose from the rear panel of the machine and
connect a temporary pipe
• push and release the torch button once: the test unit pump cooling must be
activated for 15 seconds.
• The liquid should exit the temporary tube, if it does not come out repeat the
previous test by pressing the torch trigger again
• once the correct flow of liquid is guaranteed, restore the original tube
• if necessary, check the correct flow of liquid flowing at the inter-average levels, ie
on the external thread feeder.
When the generator is equipped with the cooling unit, When the generator is equipped with the cooling unit, THE USER'S UTILIZER MUST
VERIFY THE PRESENCE AND THE CORRECT CIRCULATION TO VERIFY THE PRESENCE AND THE CORRECT CIRCULATION OF THE COOLING
LIQUID. COOLING DOWN..
Failure to control could result in damage to equipment and torches. Failure to control could result in damage to equipment and torches. The
cooling unit unit only works when the Mig, Pulsed Mig or Cooling Tig process is activated. It only works when the Mig, Pulsed Mig or Tig
processes are activated. The unit's cooling pump is activated when the torch button is pressed and the unit's cooling pump is activated when
the torch button is pressed and goes off 4 minutes after the end of the welding job. 4 minutes after the end of the work welding.
When the generator is equipped with the cooling unit, the correct circulation of the
coolant is constantly monitored. The cooling unit only works when the Mig, Pulsed
Mig or Tig processes are activated. The unit's cooling pump is activated when the
torch button is pressed and goes off 4 minutes after the end of the welding job.
In case of liquid circulation failure, the output is deactivated and display shows:
Cooling unit WITH flow control switch H2O
AL H2o
Cooling unit WITHOT flow control switch H2O