10
mm
M形
M type
補助スイッ
M形 M Type B形 B Type
M形 M Type B形 B Type
T2AX00M
T2AL00M
T2SH00 T2UV00
警報スイッ Alarm Switch
電圧引外し
Shunt Trip
不足電圧引外し
Undervoltagie Trip
* *
* *
* *
Auxiliary Switch
T2AX00B
T2AL00B
Innovators in Protection Technology
5470002 大阪市平野区加美東7
2
10
電話:06(6791)9320
ファックス:06(6791)9274
ホームページ:http://www.terasaki.co.jp
E-mail:kiki-info@terasaki.co.jp
2G0331SAJ(KRB-0335j)
7-2-10 Kamihigashi, Hiranoku, Osaka
547-0002, Japan
TEL:81-6-6791-9323/ FAX:81-6-6791-9274
URLhttp://www.terasaki.co.jp
E-mailint-sales@terasaki.co.jp
形式Types
・固(Fix Types
S50-GF
S100-NF S100-GF H100-NF L100-NF
E225-NF S225-NF S225-GF H225-NF
L225-NF S125-NF S125-GF H125-NF
L125-NF E250-NF S250-NF S250-GF
H250-NF L250-NF
可調整形
Adjustable Thermal Magnetic Types
E125-NJ S125-NJ S125-GJ H125-NJ L125-NJ
S160-NJ H160-NJ L160-NJ
E250-NJ S250-NJ S250-GJ H250-NJ L250-NJ
電子式
S225-GE S225-PE H225-NE S250-PE H250-NE
ノーヒューブレ
取扱説明書
Instruction Manual for Moulded
Case Circuit Breakers
x 内容物一覧/必要となる工具 Packaged Items/Assembly Tools c 操作と動作 Operating Instructions v 内部付属品の着脱 Fitting Internal Accessories
*付属品の図記号
Symbols of Accessories
リングマーク Ring Mark
ブレーカ
Breaker
:1
取扱説明書
Instruction
1
2P:1
3P:2
4P:3
取扱説明書
(本書)
Instruction Manual
(This document)
端子バリア(FCのみ)
Interpole Barrier
(Only FC)
4
8
10 1713
5 6
RESET
TRIPPED
(OFF)
付属品取付け後必ず正常に動作するを確 認してから,ご使 さい
After fitting, verify the function of the Accessory.
ON
ハンドル
Handle
OFF
ップ ボタン
Trip Button
取外し Removal
AX
AL
SH
UV
V
f
g
h
i
f
g
h
i
裏面の溝に沿
f,g,h,iのいず
れかを切して
下さい
Cut off f,g,h,i along
the grooves carved
on the back.
電線引き出し部の処理 Pull Out Leads on Load Side組み合せ Combination
補助スイッチ
Auxiliary Switch
警報スイッチ
Alarm Switch
a接点
a contact
b接点
b contact
a接点
a contact
b接点
b contact
11/AXc-14/AXa 11/AXc-12/AXb
91/ALc-
94/ALa
91/ALc-
92/ALb
21/AXc-24/AXa 21/AXc-22/AXb
電圧引外し電源
Shunt Trip
power source
C1-C2
不足電圧引外し電源
Undervoltage Trip
power source
D1-D2
本説明書ご使用になる方のお手元で大切に保管て下本書に述い取扱い
及び誤った取扱いにて生る損害に関て,弊社は一切責任を負ん。
Please retain this manual for future reference.The Manufacturer assumes no
responsibility for damages resulting from non-application or incorrect application of the
instructions provided herein.
z 安全上の注意
施工,使用,保守点検の前に必ず本その他の付属書類お読み頂機器の知識,安全の情
報,及び注意事項の全に習熟らお さいこの取扱説明書では,安全注意事項の
ランクを 険」,「注意」して 分してあます
取扱いを誤った場合に,危険な状況が起えて,死亡たは重傷を受ける可能性が
想定れる場合。
:取 危険な状況て,中程度の傷害や軽傷を受ける
可能性が想定れる場合。
なお, に記した事項でも,状況によては重大結果に結びつ場合がす。
いずれも重内容ですので必ず守って下
■施工上の注意(施工に必要な各部の詳細寸法は主カタログを参照して下さい。
■使用上の注意
●電気工事有資格者(電気工事士)が行って下
●高温,多湿,過度の塵埃,腐食性ガス,振動,衝撃ど異常環境に設置いでい。
火災の原因なったり,正常に動作れがます
●ゴコンクリト粉鉄粉の異物及び雨水なーカ 入らないうに
施工て下い。火災の原因なったり,不動作のます
施工作業上位を○OFFにし 充電ていを確 認して行って下さい。
感電のれがます
●4形ブレーカの場相4線 ずN極 接続て下い。過電流
動作せに火災の原因ます
●端子ね標準締付トルクで 付けて下さ火災の原因ます
●端子ねじの締付け時及び接続後,端子部に無理な力が
加わないうにして下さい端子部への過大な応力
火災のれがます
●表形ブレーカ電側の裸導体間ブレーカ
まで 縁し下さい 端子バアが同梱場合は必ず使用絶縁テプ等
端子バ重なで絶て下さい 不十分な絶縁は電源短絡すます
●アス排出口はアースペ(絶縁距離)十分確保て下さい 遮断で
きない あります
注意
●端子部に触れないで下感電のおそれがあます。
危険
●自的にトリップ(遮断)した 合は原因を取除いドルを|ONにし
下さい (短絡電流)を遮した場 は,ブレーカを 検し下さい
おそれがあります
注意
危険
注意
注意
端子
バリア
絶縁チューブ
または
絶縁テープ
z Safety Notices
Be sure to read these Instructions and other associated documents accompanying the
product thoroughly to be familiarize yourself with the product handling, safety information, and
all other precautions before mounting, using, servicing, or inspecting the product. In these
Instructions, safety notices are divided into "Warning" and "Caution" according to the hazard
level:
: A warning notice with this symbol indicates that neglecting the suggested
procedure or practice could result in lethal or serious personal injury.
: A caution notice with this symbol indicates that neglecting the suggested
procedure or practice could result in moderate or slight personal injury and/or property damage.
Note that failing to observe notices could result in serious results in some cases.
Because safety notices contain important information, be sure to read and observe them.
■保守・点検上の注意
■そ 他の 注意
・付属装置のド線を持って持ち運びしないで下故障の原因ます。
・ブレーカの本体のカバーは開けないで下性能と品質を保証ません。
・ブレーカに接続する電線や導体は定格電流に適た断面積のものを使用して下
断面積が小と,不要動作及び過熱のおそれがあます。
Other Precautions
Do not carry this product by accessory leads, as this may cause damage to the
product.
Unauthorised opening of the breaker cover will invalidate product warranty.
When installing the product, use wires or conductors, the cross sectional areas of
which accommodate the rated current of the product. Using wires or conductors with
inadequate cross sectional areas may cause false tripping and overheat.
●保守点検専門知識有する人が行て下い。
●保守点検は上位を○OFFし,充電いこを確認して行って下さい。
感電のれがます
●端子ね定期的に標準締付トルクで増し締して 火災の原因ます
注意
Mounting Precautions
(For detailed mounting dimensions, refer to the TemBreak2 catalogue.)
Electrical work should only be undertaken by suitably qualified persons.
Do not place the product in an area that is subject to high temperature, high humidity,
excessive dusty air, corrosive gas, strong vibration and shock, or other unusual
conditions. Mounting in such areas could cause a fire or malfunction.
Be careful to prevent foreign objects (debris, concrete powder, iron powder, etc.) and
rainwater from entering product. These materials inside the product could cause a fire
or malfunction.
Prior to commencing any work on the product, open an upstream circuit breaker or isolator to
ensure that no voltage is applied to the product. Otherwise, electrical shock may result.
For 4-pole breakers, be sure to connect a neutral conductor to the N pole. Otherwise, an
over-current may hinder the product from tripping, thus resulting in a fire.
Caution
Handling Precautions
Never touch terminals. Otherwise, electric shock may result.
Warning
When the breaker trips open automatically, remove the cause, then return the
handle to the |(ON) position. Should a fault be interrupted, the breaker must be
inspected. Otherwise, a fire may result.
Caution
When connecting cable or busbar to the product, tighten terminal screws to the torque
specified in this manual. Otherwise, a fire could result.
Even when tightening the terminal screws and
after conductor connection, do not apply excessive
force to the terminals. Otherwise, a fire may result.
For front-connected breakers, Insulate all bare
conductors of the line side until the breaker end. If interpole barriers are packed, be
sure to use the barriers; moreover, insulate all bare conductors by insulating tape or the
like so that the tape overlaps with the barriers. Insufficient insulation may result in short-
circuit.
Do not block the arc gas vents of the product to ensure adequate arc space. Blocking
these vents could result in failure of circuit interruption.
Maintenance Precautions
Service and/or inspection of the product must be done by persons having expert
knowledge.
Before servicing or inspecting the product, open an upstream circuit breaker or the
like to isolate all sources of power. Otherwise, electric shock may result.
Regularly check that the breaker terminal screws are tightened to torque values
shown within this manual, failure to do so may result in fire.
Caution
interpole
barriers
insulating tubes
or
insulating tape
Warning
Caution
Caution
操作
Operation
ハンドル操作力
Operation effort
Type 1
(OFF)⇒|(ON)
22N
(OFF)⇒|(ON)
25N
(ON)⇒○(OFF)
28N
TRIP⇒○(OFF)
68N
Type 2
Type 3
Type 4
(ON)⇒○(OFF)
36N
TRIP⇒○(OFF)
76N
接続/極数
Connections/Poles
形式 Type
Type 1
Qty
S50-GF S100
E125 S125
表面形FC
Front
Connected
2P
4
a:M8×16
3P
6
4P
8
2P
2
2P
2
b:M4×80
3P
2
差込形PMB
Plug-in
Connected
50 / 100 / 125AF
Type 2 Type 3 Type 4
100 / 125AF 160 / 225 / 250AF 160 / 225 / 250AF
Qty
H100 L100
H125 L125
Qty
S160 E225 S225
E250 S250
Qty
H160 L160 H225
L225 H250 L250
d:M8×20 d:M8×20 d:M8×20
6 6 6
8 8 8
b:M4×115 b:M4×80 b:M4×115
4 2 4
b:M4×55 b:M4×90 b:M4×55 b:M4×90
3P
2 2 2 2
4P
4 4 4 4
裏面形RC
Rear
Connected
2P
4
c:M8×25 c:M8×25 c:M8×25 c:M8×25
3P
6 6 6 6
4P
8 8 8 8
2P
2
b:M4×55 b:M4×90 b:M4×55 b:M4×90
3P
2 2 2 2
4P
4 4 4 4
4P
4 4 4 4
埋込形F.P
Flush Plate
Where
Applicable
2P
4
c:M8×25 c:M8×25 c:M8×25 c:M8×25
3P
6 6 6 6
4P
8 8 8 8
2P
4
e:M5×16 e:M5×16 e:M5×16 e:M5×16
3P
4 4 4 4
4P
4 4 4 4
a: b: c: d: e:
差込形PMC
Plug-in
Connected
3P
2
b:M4×58
4
b:M4×100
2
b:M4×65
4
b:M4×100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TERASAKI S100-NF and is the answer not in the manual?

TERASAKI S100-NF Specifications

General IconGeneral
BrandTERASAKI
ModelS100-NF
CategoryOther
LanguageEnglish

Related product manuals