RMX SERIES
2-8
483018 - 3/15 Terex South Dakota RMX Series
MAINTENANCE GUIDELINES
STORAGE PROCEDURE
When a unit will not be used for a period of time, it should be prepared for storage to reduce the deteriorating
effects of the environment. This includes the following:
Wash and clean to remove accumulated road grime. It can discolor the paint if left on for long periods
of time.
Clean and wax the fiberglass components. If storage is in the sun, cover the booms.
Clean and coat the exposed cylinder rods with grease, preservative spray or heavy preservative oil.
Clean and grease the exposed valve spools and linkage.
Lubricate the entire Aerial Device following the lube chart.
Check the oil for pH level and water content. Acidic oil or water in the oil may settle out during storage
and can rust the interior of the hydraulic system.
Cover the platform to prevent water from accumulating. A platform full of water can weigh over 900
lbs. (408 kg) and exceed the capacity of the platform.
Ensure the hydraulic tank filler-breather filter is intact to prevent dirt entering the tank when the
temperature changes.
Grease all sliding surfaces where there is metal contact to prevent rust.
Touch up any bare metal and where the paint is chipped or cracked.
Spray the electric collector commutators with LPS 1 or CRC 5-56 to prevent corrosion of the surface.
Service the truck as recommended by the manufacturer.
NOTE: The period of time between uses when the unit should be prepared for storage varies with
the location. If the climate is temperate and dry it may be 4 months. If it is in a humid area
next to the ocean with the salt air it may be only 2 weeks.