Section 120-0010
Transmission - Transmission and Mounting
SM 1965 4-00
18
Fault MEANING OF CODE TCU reaction Checks Remarks
Code possible reason for fault detection
(hex)
A1 S.C. TO GROUND AT DIFFLOCK SOLENOID no reaction check cable from TCU to
1)
see figure 8
TCU detected a wrong voltage at the output pin, that OP-Mode: normal difflock solenoid
looks like a s.c. to vehicle ground check connectors from
cable is defective and is contacted to vehicle ground difflock solenoid to TCU
difflock solenoid has an internal defect check resistance
1)
of
connector pin is contacted to vehicle ground difflock solenoid
A2 S.C. TO BATTERY VOLTAGE AT DIFFLOCK SOLENOID no reaction check cable from TCU to
1)
see figure 8
TCU detected a wrong voltage at the output pin, that OP-Mode: normal difflock solenoid
looks like a s.c. to battery voltage check connectors from
cable is defective and is contacted to battery voltage difflock solenoid to TCU
difflock solenoid has an internal defect check resistance
1)
of
connector pin is contacted to battery voltage difflock solenoid
A3 O.C. AT DIFFLOCK SOLENOID no reaction check cable from TCU to
1)
see figure 8
TCU detected a wrong voltage at the output pin, that OP-Mode: normal difflock solenoid
looks like a o.c. for this output pin check connectors from
cable is defective and has no connection to TCU difflock solenoid to TCU
difflock solenoid has an internal defect check resistance
1)
of
connector has no connection to TCU difflock solenoid
A4 S.C. TO GROUND AT WARNING SIGNAL OUTPUT no reaction check cable from TCU to
1)
see figure 8
TCU detected a wrong voltage at the output pin, that OP-Mode: normal warning device
looks like a s.c. to vehicle ground check connectors from
cable is defective and is contacted to vehicle ground warning device to TCU
warning device has an internal defect check resistance
1)
of
connector pin is contacted to vehicle ground warning device
A5 O.C. AT WARNING SIGNAL OUTPUT no reaction check cable from TCU to
1)
see figure 8
TCU detected a wrong voltage at the output pin, that OP-Mode: normal warning device
looks like a o.c. for this output pin check connectors from
cable is defective and has no connection to TCU warning device to TCU
warning device has an internal defect check resistance
1)
of
connector has no connection to TCU warning device
A6 S.C. TO BATTERY VOLTAGE AT WARNING SIGNAL OUTPUT no reaction check cable from TCU to
1)
see figure 8
TCU detected a wrong voltage at the output pin, that OP-Mode: normal warning device
looks like a s.c. to battery voltage check connectors from
cable is defective and is contacted to battery voltage warning device to TCU
warning device has an internal defect check resistance
1)
of
connector pin is contacted to battery voltage warning device
B1 SLIPPAGE AT CLUTCH K1 TCU shifts to neutral check pressure at clutch K1
TCU calculates a differential speed at closed clutch K1. OP-Mode: limp home check main press. in system
If this calculated value is out of range, TCU interprets if failure at another check sensor gap at internal
this as slipping clutch. clutch is pending speed sensor
low pressure at clutch K1 TCU shifts to neutral check sensor gap at output
low main pressure OP-Mode: TCU shutdown speed sensor
wrong signal at internal speed sensor check signal at internal
wrong signal at output speed sensor speed sensor
wrong size of the sensor gap check signal at output
clutch is defective speed sensor
replace clutch
B2 SLIPPAGE AT CLUTCH K2 TCU shifts to neutral check pressure at clutch K2
TCU calculates a differential speed at closed clutch K2. OP-Mode: limp home check main press. in system
If this calculated value is out of range, TCU interprets if failure at another check sensor gap at internal
this as slipping clutch. clutch is pending speed sensor
low pressure at clutch K2 TCU shifts to neutral check sensor gap at output
low main pressure OP-Mode: TCU shutdown speed sensor
wrong signal at internal speed sensor check signal at internal
wrong signal at output speed sensor speed sensor
wrong size of the sensor gap check signal at output
clutch is defective speed sensor
replace clutch