Declaration of Performance
TT21-CPR-2016-Version1
Product:
Product type/application: Room heater burning solid fuel without hot water supply
Type: TT21R: S01-630/631 TT21RS: S01-632/633 TT21RL: S01-628
TT21RLS: S01-634 TT21RH: S01-636 TT21RHS: S01-638
Fuel: Wood
Productions no. Please see nameplate on the back of the oven
Manufacturer:
TermaTech A/S E-mail: info@termatech.com
Gunnar Clausens Vej 36 Web: www.termatech.com
8260 Viby J Tel.: +45 8742 0035
Denmark
Certification and requirements:
AVCP system: System 3
European standard: DS/DIN/EN 13240:2001 + A2:2004/2007
Certification: Rhein-Ruhr Feuerstätten Prüfstelle GmbH, notified body no. 1625, has
performed determination of the product type and declared performance on the
basis of type testing and issued test report no. 40 16 4435. Teknologisk Institut,
notified body no. 1235, has performed determination of the product type and
declared performance on the basis of type testing and issued test report no.
300-ELAB-1520-SIK-Rev-1.
Declared performance:
The undersigned is responsible for the manufacturing and conformity with the declared performance.
1.12.2016 Søren Toft______________________________
Essential characteristics
Performance Harmonised technical
Reaction to fire AI
DS/DIN/EN 13240:2001
+ A2:2004/2007
Distance to combustible materials
Rear: min. 150 mm
Sides: min. 350 mm
Other safety distances – please see User
and mounting manual
Emission of combustion products
NOx = 125 mg/m³
OGC = 107 mgC/Nmᶟ
PM = 24 mg/m³
Risk of burning fuel falling out Passed
Surface temperature Passed
Mechanical strength Passed
Emission of hazardous materials
Flue gas temperature 273° Celsius
Output 5,0 KW