The stove is difcult to control – it burns too fast
If the stove is new, then check that the directions have been follo-
wed. If the stove is more than 1 year old or if it has been used he-
avily, then the jointings may need to be changed. If the jointings sit
for too long the heat makes them lose their ability to keep the stove
sealed. If there is heavy draught in the chimney it may be necessary
to t a damper in it.
The stove has poor draught after installation
Check that the mounting instructions have been followed. It is espe-
cially the conditions surrounding the chimney that may cause pro-
blems. Are diameter and length okay, is it sealed, are smoke pipe
and junctions sealed? Is the cleaning hatch sealed? You may need
to contact a chimney sweep to remedy the problem as the chimney
may be blocked.
Smoke and soot smell
This can be caused by down-draught in the chimney and most often
happens in specic wind directions. The chimney may be too short
for the ridge or trees may have grown and are creating turbulence.
Remember not to open the door while there are ames.
The stove is difcult to light and may die out
There may be a number of causes. The most typical are:
The damper is not sufciently open.
The rewood is too wet.
The draught in the chimney is too small or maybe it is blocked or
leaking.
The ember layer was too small/incinerated and did not give
enough heat to light the logs. Possibly give some start-up air to
the re by opening the damper (pushed down and to the right)
to get the stove going again. Then the damper has to be closed
again (back to position between left and the middle).
Depending on the problem it may be necessary to contact the dea-
ler, installer or a chimney sweep.
The glass soots up
The wood is too moist.
Lack of draught in the chimney.
Check that the damper is not closed.
Door is closed too early at lighting (point 3 section 2).
TECHNICAL SPECIFICATIONS
TT22 TT22S
Nominal heat output 7,5 kW 7,5 kW
Height: 929mm 949mm
Width: 708mm 708mm
Depth: 482mm 482mm
Weight: ca. 175kg ca. 208kg

Other manuals for TermaTech TT22

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TermaTech TT22 and is the answer not in the manual?

TermaTech TT22 Specifications

General IconGeneral
BrandTermaTech
ModelTT22
CategoryWood stove
LanguageEnglish

Related product manuals