Terumo Terufusion LF3 User Manual

Terumo Terufusion LF3
238 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Terumo Terufusion LF3 and is the answer not in the manual?

Terumo Terufusion LF3 Specifications

General IconGeneral
ManufacturerTerumo
ModelTerufusion LF3
Accuracy±5%
Power SupplyAC 100-240V, 50/60Hz
Infusion Volume Range1 to 9999 mL
Bolus Volume Range0.1 to 500 mL
DisplayLCD
AlarmsOcclusion, Air-in-line, Low Battery, Door Open
Compatible Administration SetsTerumo dedicated infusion sets

Summary

Purpose, Overview and Features of the Product

Features

Details the key functionalities and advantages of the infusion pump.

Easy-to-read display

Describes the 4.3-inch color LCD for clear visibility and status indication.

Wide range of alarm functions

Lists various alarms like battery, occlusion, and flow rate abnormalities for safety.

Parts Description

Exterior Diagram

Illustrates and labels the external components of the infusion pump.

Operation Panel

Explains the function of each switch and the operation indicator on the pump.

Screen Description

Details the information displayed on the pump's flow rate screen.

Status icon display

Explains the meaning of various icons shown on the pump's status display.

Precautions

Warnings

Highlights potential risks of death or serious injury if precautions are not followed.

Cautions

Outlines potential risks of personal injury or property damage if precautions are not followed.

Preparation

Prior-to-use Inspection

Lists checks to ensure the pump and accessories are undamaged and functional before use.

Connecting to AC Power

Provides instructions for connecting the pump to an AC power source for operation and charging.

Operating by the Internal Battery

Explains how the pump operates on its internal battery and its limitations.

Operation Procedure

Preparing an Infusion Set and Priming

Guides through setting up the infusion set and priming the line before starting delivery.

Setting Flow Rate

Details how to adjust the infusion flow rate per hour using the pump's controls.

Setting VTBI

Explains how to set the Volume To Be Infused (VTBI) for the infusion.

Starting Solution Delivery

Provides steps to begin the infusion process after setting parameters.

Changing Settings on the Menu

Occlusion Detection Pressure

Explains how to set the pressure sensitivity for occlusion alarms in 10 levels.

Keypad Lock Function

Details how to enable or disable the keypad lock to prevent inadvertent operations.

Bolus

Explains how to perform bolus infusions using Hands On or Hands Free methods.

Troubleshooting

High priority alarm

Addresses issues causing high-priority alarms like Air-in-line and Occlusion alarms.

Low priority alarm

Covers troubleshooting for low-priority alarms such as No Flow Rate and No VTBI.

Nearly Empty alarm

Provides actions for when the drug solution container is nearly empty.

Specifications

Main unit

Lists technical specifications for the pump's main unit, including ranges and accuracy.

Units Available

Details the different models, catalogue numbers, plug types, and interfaces available.

For Medical Staff

EMC Technical Information

Provides essential information for the safe installation and use of the equipment regarding EMC.

Guidance and manufacturer’s declaration – electromagnetic immunity

Declares compliance with electromagnetic immunity standards and guidance for safe operation.

Symbols

Description of Symbols

Explains the meaning of various symbols and icons used on the pump and its display.