CAUTION: To avoid damaging the
vehicle, do not allow the positive
cable to contact other metal
components.
5.
The HEPA filter bolt (as shown in the
following image to the right) serves as the
negative jump post. Connect the external
low voltage power supply’s black
negative (-) cable the black negative (-)
jump post.
6.
Turn on the external power supply (refer
to the manufacturer’s instructions) for
20-30 seconds.
CAUTION:
If you leave the power
supply on for longer than 30
seconds, the low voltage battery
may not self-recover and the
vehicle might not be able to shift
into Drive. Disconnect the power
supply and the low voltage battery
to enable another battery self-
recovery attempt.
NOTE: If attempting to activate Transport
Mode (to winch the vehicle onto a
flatbed
truck), the low voltage battery is not
required to self-recover. Leave the power
supply connected continuously until the
vehicle has been secured.
7. Open the driver door and wait two
minutes.
8. Ensure the vehicle is able to shift into
Drive.
9.
Replace the maintenance panel by placing
it back in its original location and pressing
down until it is secure.
10.
Close the hood.
Instructions for Transporters