16
ENG
Description Reason Solution
Water leakage The connection between
inlet pipe or outlet hose is
not tighten
Check and fasten water pipes
Clean up outlet hose
Detergent residues in
the box
Detergent is dampened or
agglomerated
Clean and wipe the detergent box
Indicator or display does
not light
Disconnect the power
PC board or harness has
connection problem
Check if the power is shut down and the
power plug is connected correctly
Abnormal noise Check if the fixing (bolts) have been removed
Check it’s installed on a solid and level floor
Technical Specifications
MAX. Current 10A
Standard Water Pressure 0.05MPa~1MPa
D
W
H
Power Supply 220-240V~,50Hz
Washing Capacity 8.0kg
Dimension (W*D*H) 595*565*850
Weight 68kg
Rated Power 2000W
Description Reason Solution
Door is not closed properly Restart after the door is closed
Check if the clothes is stuck
Water injecting problem
while washing
Check if the water pressure is too low
Straighten the water pipe
Check if the inlet valve filter is blocked
Overtime water draining Check if the drain hose is blocked
Water overflow Restart the washer
Others Please try again first, call up service line if there
are still troubles
NOTE
• After the check, activate the appliance. If the problem occurs or the display shows other alarm codes
again, contact the service.