17. Maintenance
Interval
Part
Every time
For every
20 running
hrs
For every
50 running
hrs
For every
100
running hrs
For every
200
running
hrs
Inspect bolts and nuts
X
Inspect and fill with oil
X
Change oil
X
X
Clean / replace oil filter
X (clean)
X (clean)
Inspect for oil leakage
X
Inspect air filter
X
Clean air filter
X
Inspect paper filter
Inspect and replace element when needed.
Clean fuel filter
X
Inspect sparking plug
X
Inspect fuel pump
X
Adjust valves
X
Inspect valves
X
18. Specifications
Model
TG 620 B
Type
4 stroke, air-cooled OHV, 1 cylinder, gasoline
engine
Drilling x length of stroke mm
64 x 54
Stroke volume L
0,179
Max power kW (HP) / rev/min
3,5 (5,0) / 3600
Constant power kW (HP) / rev/min
3,2 (4,5) / 3600
Fuel
Leadless gasoline octane 95
Fuel capacity
3,6 L
Fuel consumption (g/PS.h)
275
Lubrication oil
SAE10W30
Lubrication oil capacity
0,6 L
Starting system
Recoil
Sparking plug
F6RTC / 20EPR-V / Art no 10011219
Regulation system
Mechanic
Rotating direction of PTO
Clockwise, Seen from the side of the PTO
Dimension (L x W x H), cm
39 x 32 x 34,5
Dry weight, kg
15,5
NOTE
- The purpose of maintenance is to keep the engine in its best possible shape.
- Repairs should always be carried through by an authorized Power Line dealer.