EasyManua.ls Logo

Texecom PREMIER 168 - Areas; Monitoring

Texecom PREMIER 168
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Premier 48, 88 & 168 Factory Defaults and Quick Reference Guide Quick Reference Guide
INS222 5
2. Quick Reference Guide
!
Log Off Engineer
"#
Press
"
to log out of the Engineer Programming menu
$
Zone Setup
"#
Zone Types
Use
$
-
%
to enter zone number,
&
to edit,
!
-
'
or
(
to select a
zone type,
"
to accept
#
!
Not Used
(
Medical
#
!
$
Entry/Exit 1
(
24Hr Gas
#
!
)
Entry/Exit 2
(
Auxiliary
#
!
*
Guard
(
Tamper
#
!
+
Guard Access
(
Exit Terminator
#
!
,
24Hr Audible
(
Moment Key
#
!
-
24Hr Silent
(
Latching Key
#
!
.
PA Audible
(
Security
#
!
%
PA Silent
(
Omit Key
#
!
'
Fire
(
Custom
"#
Zone Attributes 1 Press
&
to edit,
$
-
%
to select an attribute,
"
to accept
#
$
O = Omittable
,
3 = Part 3 Omit
#
!
)
F = Force Omit
-
A = Access
#
!
*
1 = Part 1 Omit
.
E = Entry/Exit 2
#
!
+
2 = Part 2 Omit
%
G = Guard
"#
Zone Attributes 2 Press
&
to edit,
$
-
%
to select an attribute,
"
to accept
#
$
D = Double Knock
,
R = Reset
#
!
)
B = Beam Pair
-
A = Auto Re-arm
#
!
*
S = Soak Test
.
Q = Quick Resp.
#
!
+
F = Activity
%
E = Eng. Alarm
"#
Key Attributes Press
&
to edit,
$
-
,
to select an attribute,
"
to accept
#
$
I = Instant Arming
,
S = Silent Arming
#
(only applicable for
keyswitch zone types)
!
)
P = Part Arming
-
T = Time Arm Disable
#
!
*
F = Full Disable
.
K = Key Tube (Monitor Only)
#
!
+
D = Disarm Only
"#
Custom Attributes Press
&
to edit,
$
-
,
to select an attribute,
"
to accept
#
$
B = Bell/Strobe
+
C = Enable Coms
#
(only applicable for
custom zone types)
!
)
I =Internals
,
W = Warning
#
!
*
M = Monitor 24Hr
"
Zone Areas
Press
&
to edit,
$
-
%
to select an area, (
!
= all areas,
/
= areas A – H and
I –P),
"
to accept.
"#
Zone Text
Press
&
to edit,
!
-
'
to select characters (press the required key the appropriate
number of times),
"
to accept
#
$
. , ? ! 1 @ “ -
-
M N O 6
(
Move Cursor
#
!
)
A B C 2
.
P Q R S 7
0
Copy Text to Memory
#
!
*
D E F 3
%
T U V 8
1
Paste Text from Memory
#
!
+
G H I 4
'
W X Y Z 9
&
#
!
,
J K L 5
!
0 _
Upper, Lower Case, Predictive
Text and Numerical
"#
Zone Chime Press
&
to alter chime tone,
"
to accept
&#
Silent
&
Chime 1
&
Chime 2
&
Chime 3
"#
Zone Mask Press
&
to alter Mask option,
"
to accept
"#
Zone Wiring Press & to alter wiring type,
" to acce
p
t
#
!
!
Normally Open
*
Triple EOL
-
2K2/4K7/(6K8)
#
!
$#
Normally Cosed
+
1K/1K/(3K)
.
4K7/4K7
#
!
)#
Double Pole EOL
,
4K7/6K8(12K)
%
WD Monitor