STEP 1 Remove the four screws as shown in fig 1 using a Phillips head
screwdriver.
STEP 2 Let the service panel hang down as shown in fig 2.
STEP 3 You can now check the wire connection from the igniter to the
spark tip.
STEP 4 Replace the service panel as shown in fig 3 and retry.
** NEVER TRY TO IGNITE THE MIDGEATER WHEN THE
SERVICE PANEL ** IS REMOVED AS IN FIG 2.
STEP 5 If the problem persists a Texol engineer should be called to
rectify the fault.
NOZZLE HOUSING BLOCKAGE: Assuming that the regulator is fitted
properly and the igniter is sparking, the next check is the Nozzle
Housing. This can become blocked due to spiders casting a web inside
the housing, this restricts the gas flow which does not allow the
combustion process to occur. See figure 4 below.
The nozzle housing can be cleared with the use of an air duster aerosol
dispenser (supplied in customer kit). Firstly remove service panel as
before, then using the tube attachment on the air duster, insert the tube
into the nozzle housing through the air vents. Try to get the tube pointing