CONDITIONS
(CONT.)
Fuel
Max.
*Max.
Cons.
Oil Cons.
Cyl. Head
Operation
RPM
HP
Gal./Hr.
Qts./Hr.
Temp.
10-540-AC
Series
Normal
Rated
2700
300
23.7
0.98
480°F.(249°C.)
Performance
Cruise
(75%
Rated)
2400
225
19.0
0.73
480°F.(249°C.)
Economy
Cruise
(60%
Rated)
2200
180
12.6
0.58
480°F.(249°C.)
e.
Engine
Shut
Down
-
(1)
Set
propeller
at
minimum
blade
angle
(high
RPM).
(2) Idle
until
there
is a
decided
decrease
in
cylinder
head
tempera-
ture.
(3)
Move mixture
control
to "Idle
Cut-off".
(4)
When
engine
stops,
turn
ignition
switch
off.
3-18
Revised
January
1999