EasyManua.ls Logo

TFA 35.1124 - Delivery Contents; Range of Application and Benefits; Safety Information; Risk of Injury Warnings

TFA 35.1124
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2120
Maritime weather station
Start the outdoor transmitter manual search
Choose another place for the outdoor transmitter and/or the base station
Reduce the distance between the outdoor transmitter and the base station
Check if there is any source of interference
No DCF reception Activate (DCF ON) the DCF reception in setting mode
Press and hold the MAX/MIN/– button for 3 seconds to activate the reception manually.
Wait for an attempt reception during the night
Choose another place for your device
Set the clock manually
Check if there is any source of interference
Restart the instrument according to the manual
Incorrect indication Restart the device
Change the batteries
If your device fails to work despite these measures, please contact the retailer where you purchased the product from for advice.
14. Waste disposal
This product and its packaging have been manufactured using high-grade materials and components which can be recycled and reused. This reduces
waste and protects the environment.
Dispose of the packaging in an environmentally friendly manner using the collection systems that have been set up.
Disposal of the electrical device
Remove non-permanently installed batteries and rechargeable batteries from the device and dispose of them separately.
This product is labelled in accordance with the EU Waste Electrical and Electronic Equipment Directive (WEEE).
This product must not be disposed of in ordinary household waste. As a consumer, you are required to take end-of-life devices to a designat-
ed collection point for the disposal of electrical and electronic equipment, in order to ensure environmentally-compatible disposal. The return
service is free of charge. Observe the current regulations in place!
Disposal of the batteries
Never dispose of empty batteries and rechargeable batteries with ordinary household waste. They contain pollutants which, if improperly dis-
posed of, can harm the environment and human health. As a consumer, you are required by law to take them to your retail store or to an
appropriate collection site depending on national or local regulations in order to protect the environment. The return service is free of charge.
The symbols for the contained heavy metals are: Cd=cadmium, Hg=mercury, Pb=lead.
15. Specifications
Temperature 0 °C… +50 °C
Resolution 0.1°C
Accuracy ±1°C
Humidity 10…99% RH
Accuracy ±5% RH (@25°C, 30%...80%RH
Resolution 1%RH
Maritime weather station
Atmospheric pressure 800 hPa …1100 hPa
Accuracy ±1 hPa
Resolution 0.1 hPa
Update interval Every 30 seconds
Base station
Power consumption 2 x AA 1,5 V batteries (not included)
Dimensions 160 x 160 (152) x 32 (87) mm
Weight 247 g (device only)
Transmitter (optional) Cat. no. 30.3249.02
Range max. 100 m (open field)
Transmission frequency 433 MHz
Maximum
radio-frequency power < 10mW
No part of this manual may be reproduced without written consent of TFA Dostmann. The technical data are correct at the time of going to print and may change without prior notice.
The latest technical data and information about this product can be found in our homepage by simply entering the product number in the search box.
EU Declaration of conformity
Hereby, TFA Dostmann declares that the radio equipment type 35.1124 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the
following internet address: www.tfa-dostmann.de/service/downloads/ce
www.tfa-dostmann.de
E-Mail: info@tfa-dostmann.de
TFA Dostmann GmbH & Co.KG, Zum Ottersberg 12, 97877 Wertheim, Germany 05/23