TGI-415 FILTRATION PROCESS
SPECIFICATIONS:
1st stage: Sediment filter, 5 micron, 10”
2nd stage: Carbon block filter, 5 micron, 10”
3rd stage: TFC membrane, 30GPD @ 60PSI / 45GPD @ 100PSI
4th stage: Inline carbon filter
Auto shut off valve
Operating pressure: 50-90 PSI
Operating temperature: 40-100°F
Efficiency Rating* 17.68%
Recovery Rate** 33.22%
Daily Production Rate 10.55GPD
ITEM# DESCRIPTIONS SERVICE LIFE
IF-SP-1005 Sediment filter, 5 micron, 10” 6-12 months
FI-CTO010 Carbon block filter, 5 micron, 10” 6-12 months
MM-TFF30/45
TFC membrane, 30GPD @ 60 PSI / 45 GPD @ 100 PSI
24-36 months
FI-CBA010J.38 Inline carbon filter 12-18 months
REPLACEMENT PARTS
2nd STAGE
3rd STAGE
PRESSURE TANK
1st STAGE
TO FAUCET
4th STAGE
TO FEED WATER
CHECK VALVE
TO DRAIN
AUTO SHUT OFF VALVE
Please contact your local dealer at:
Or call TOPWAY GLOBAL INC. at 800-840-1688 for your local dealer
listing phone number
*Efficiency Rating means the percentage of influent water to the system that is available to the user as reverse osmosis treated water
under operating conditions that approximate typical daily usage.
**Recovery Rating means the percentage of influent water to the membrane portion of the system that is available to the user as reverse
osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed.
TGI RO System Manual Series D Manual
4