Do you have a question about the Thermia Calibra and is the answer not in the manual?
Simple adjustment of the indoor temperature using the control panel interface for comfortable heating.
Remote monitoring and control of the heat pump via smart phone, computer, or tablet.
System alerts for attention, presented as 'alarms' on the display for functional surveillance.
Selection of three different hot water modes (Economy, Normal, Comfort) based on user preference.
Guidelines for safe appliance use by children and persons with reduced capabilities, and user maintenance restrictions.
Requirements for qualified installers for operation, maintenance, repair, and electrical/refrigerant circuit modifications.
Overview of the heat pump system, its heating/hot water production capabilities, and main components like the compressor and control equipment.
Easy adjustment of indoor temperature via the 'comfort adjustment' feature on the start screen.
Introduction to more complex heat settings for fine-tuning indoor climate based on advanced adjustments.
Detailed guide on modifying the heat curve for fine-tuning heating settings based on outdoor temperature.
Setting seasonal stop and minimum/maximum supply line temperatures for optimal heating performance.
Guide to choosing between 'Off', 'Auxiliary heater only', and 'On/Auto' operating modes for the heat pump.
Accessing and understanding operating data like temperatures, run times, and version information for system monitoring.
Procedure for checking system pressure and topping up the heating circuit water, ensuring proper pressure levels.
Instructions for regularly checking safety valves to prevent clogging and potential water tank damage.
Steps to take in case of leakage in hot water pipes or the brine circuit, including shutting off the system.
Guidance on cleaning heating and brine circuit filters, including safety steps before starting the process.
Explanation of different alarm classes (A, B, C), their impact on the heat pump, and general handling.
Details on common alarm messages like 'High pressure', 'Low pressure', 'Internal immersion heater', and their corrective actions.
Procedure for acknowledging active alarms and resetting them to restore normal system operation.
Explanation of various symbols used in the heat pump's control interface for navigation and status indication.
Understanding how the heat pump calculates heat demand based on outdoor temperature and heat curve settings.
How to temporarily increase or decrease the indoor temperature using comfort settings on the control panel.
Detailed explanation of the heat curve, its impact on supply line temperature, and factory settings.
Configuration of supply line minimum and maximum temperatures, especially important for underfloor heating systems.