EasyManua.ls Logo

Thermo Dynamics CWL - Model Specifications

Thermo Dynamics CWL
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
HEATING CAPACITY 101,000 118,000 127,000
IBR NET RATING 88,000 103,000 110,000
INPUT 119,000 140,000 154,000
FIRING RATE .85 1.00 1.10
CHIMNEY SIZE 8 x 8 x 15 8 x 8 x 15 8 x 8 x 15
OVER FIRE PRESSURE W.C. 0-+.05 0-+.08 0-+.10
WATER CONTENT 15 GAL. 15 GAL. 15 GAL.
COIL CAPACITY 5 GAL. 5 GAL. 5 GAL.
A. JACKET HEIGHT* 29-1/2 29-1/2 29-1/2
B. JACKET WIDTH 21 21 21
C
. COIL SUPPLY HEIGHT 22 22 22
D. SUPPLY HEIGHT (HYDRONIC) 27-1/2 27-1/2 27-1/2
E. BURNER HEIGHT 7-7/8 7-7/8 7-7/8
F. HYDRONIC RETURN HEIGHT 15-1/2 15-1/2 15-1/2
G. FLUE PIPE DIA. 5 5 5
H. WASHOUT (ALT. RETURN HEIGHT) 3-1/2 3-1/2 3-1/2
I. JACKET DEPTH (INCL. FLANGE) 22 22 22
DEPTH FRONT TO REAR W/BURNER 30-3/4 30-3/4 30-3/4
HYDRONIC SUPPLY 1-1/4 1-1/4 1-1/4
HYDRONIC RETURN SIZE 1-1/4 1-1/4 1-1/4
WASHOUT (ALT. RETURN) 1-1/4 (2) 1-1/4 (2) 1-1/4 (2)
AFUE RATING - W/DAMPER 86.0 84.9 84.1
AFUE RATING - W/O DAMPER 84.3 83.2 82.1
*Specifications apply to CWL-LE, NCWL and CWL-DV except when using REAR FLUE KIT, jacket height increases by
4-1/4 inches
Model Specifications CWL 85 CWL 100 CWL 110
“0” Clearance Sides and Back
Approved for combustible Floors
Figure 1 - Model Dimensions