EPD/HB/40521/
000
ELECTRONIC PERSONAL DOSEMETER HANDBOOK
FAULTS AND RECOVERY ACTIONS
ISSUE 5
Page 74
Thermo
Services Module
Code
Text as displayed by
EasyEPD2
EPD
Action
Recommended
Customer Action
Remarks
030 Service Module stCalData
CRC faulty
Reset unit. Return to
supplier if recurs.
031 Service Module
stRateThres CRC faulty
Reset unit. Return to
supplier if recurs.
032 Service Module
stDoseThres CRC faulty
Reset unit. Return to
supplier if recurs.
033 Service Module
stDoseSummary CRC
faulty
Reset unit. Return to
supplier if recurs.
034 Service Module
stAdsData CRC faulty
Reset unit. Return to
supplier if recurs.
035 Service Module Seconds
Timer Array overflow
Reset Reset unit. Return to
supplier if recurs.
This indicates a software
fault.
036 Service Module Fine
Timer Array overflow
Reset Reset unit. Return to
supplier if recurs.
This indicates a software
fault.
037 Service Module Long
Timer Array overflow
Reset Reset unit. Return to
supplier if recurs.
This indicates a software
fault.
User I/F Module
Code
Text as displayed by
EasyEPD2
EPD
Action
Recommended
Customer Action
Remarks
040 User Interface Module
Error
Reserved for future use
Sounder Module
Code
Text as displayed by
EasyEPD2
EPD
Action
Recommended
Customer Action
Remarks
050 Sounder Module Error Reserved for future use