6-12 Evacuation and Cleanup of System Refrigeration System Diagnosis and Service
CSR-20 & CSR-40, September 1999
Evacuation Station and Unit Hook-up
1. Special, self-sealing quick disconnect couplers are required for R-404A units.
2. Gas Ballast Valve
3. Iso Valve
4. Two-stage Vacuum Pump
5. To 220/190 VAC Power
6. Calibration Standard
7. Micron Meter
8. Sensor