EasyManua.ls Logo

Thermo King Precedent S-700 - User Manual

Thermo King Precedent S-700
221 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Operator’s Manual
Operator’s Manual
Ingersoll Rand’s Climate Solutions sector delivers energy-effi cient HVACR solutions for
customers globally. Its world class brands include Thermo King, the leader in transport
temperature control and Trane, a provider of energy effi cient heating, ventilating and
air conditioning systems, building and contracting services, parts support and advanced
controls for commercial buildings and homes.
Ingersoll Rand’s Climate Solutions sector delivers energy-effi cient HVACR solutions for
customers globally. Its world class brands include Thermo King, the leader in transport
temperature control and Trane, a provider of energy effi cient heating, ventilating and
air conditioning systems, building and contracting services, parts support and advanced
controls for commercial buildings and homes.
©2012 Ingersoll-Rand Company
Printed in U.S.A.
©2012 Ingersoll-Rand Company
Printed in U.S.A.
Precedent
S-600 and S-700
TK 55538-2-OP (Rev. 3, 01/2014)
Precedent
S-600 and S-700
TK 55538-2-OP (Rev. 3, 01/2014)

Table of Contents

Questions and Answers

  • J
    James HolderAug 10, 2025
    Why is the return air temperature not within the desired range on my Thermo King Air Conditioner?
    • S
      Susan ScottAug 10, 2025
      If the return air temperature reading on your Thermo King Air Conditioner is not within the desired range, several factors could be the cause. First, the unit may not have had enough time to cool down. Check the load log history for above-temperature records and ensure the cargo compartment was properly pre-cooled. Also, the unit may have a low refrigerant charge; check the receiver tank sight glass. If no liquid is visible, a technician should add refrigerant or repair the system. The unit may also be in defrost or have just completed a defrost cycle; monitor the temperature after the cycle. Finally, the evaporator could be plugged with frost; initiate a manual defrost cycle.
  • D
    Deborah ContrerasAug 18, 2025
    What to do if there is improper air circulation in the cargo compartment of my Thermo King Air Conditioner?
    • A
      Alexander SmithAug 18, 2025
      If you notice improper air circulation in the cargo compartment of your Thermo King Air Conditioner, inspect the unit and cargo compartment to ensure the evaporator fan(s) are working correctly. Poor air circulation can result from improper cargo loading, shifting cargo, or fan belt slippage. Make corrections as needed and continue monitoring the return air temperature.
  • M
    millsronaldAug 25, 2025
    Why is the return air temperature not within the desired range on my Thermo King Accessories?
    • J
      josephcarrieAug 26, 2025
      If the return air temperature reading on your Thermo King Accessories unit is not within the desired range, several factors could be at play. First, the unit may not have had enough time to cool down. Check the load log history for above-temperature load records and pre-cooling status. Also, the unit might have a low refrigerant charge; inspect the receiver tank sight glass. If no liquid is visible, a technician should add refrigerant or repair the system. The unit may be in defrost or have recently completed a defrost cycle, so monitor the temperature after the cycle. Finally, the evaporator could be plugged with frost; initiate a manual defrost cycle.
  • S
    Steven PerezSep 1, 2025
    What to do if there is improper air circulation in the cargo compartment of my Thermo King Accessories?
    • R
      Ryan RhodesSep 1, 2025
      If you're experiencing improper air circulation in the cargo compartment of your Thermo King Accessories unit, inspect the unit and cargo compartment to ensure the evaporator fan(s) are working correctly. Poor air circulation could also stem from improper cargo loading, shifting cargo, or a slipping fan belt. Correct these issues as needed and continue monitoring the return air temperature.

Summary

EPA Emission Control System Warranty Statement

Safety Precautions

General Safety Practices

Provides fundamental safety guidelines for operating and servicing the unit.

Automatic Start;Stop Operation

Warns about the unit's automatic start capability without prior notice.

Electrical Hazard

Details dangers associated with high voltage AC power and precautions.

Battery Installation and Cable Routing

Offers safety instructions for battery handling and installation procedures.

Refrigerant Safety

Provides warnings and safety precautions regarding the handling of refrigerants.

First Aid Procedures

Offers guidance on immediate actions in case of exposure to refrigerant or oil.

Fan and Component Hazards

Alerts users to hazards associated with unit fans, belts, and high voltage components.

Ether Starting Aids Warning

Warns against the use of ether starting aids due to fire and explosion risks.

Unit Description

Control System Overview

Introduces the SMART REEFERTM 4 (SR-4) control system and its functions.

Operating Instructions

SMART REEFERTM 4 (SR-4) Controller Overview

Provides an overview of the SR-4 controller's functions and operation.

Display Modes and Setpoint Adjustment

Explains Standard and TemperatureWatch displays and how to change setpoints.

Engine and Electric Motor Start Procedures

Details procedures for starting diesel engines and electric motors.

Mode Switching Operations

Explains switching between diesel, electric, and standby modes.

Defrost and Mode Selection

Covers initiating/terminating defrost and selecting Cycle Sentry/Continuous modes.

SmartPower Electric Standby Options

Explains SmartPower standby, electric/diesel mode operations.

Remote Panel Setpoint and Mode Changes

Guides on changing setpoint and selecting Cycle Sentry/Continuous mode via rear panel.

Remote Panel Defrost and Trip Markers

Details initiating manual defrost and sending start of trip markers from the rear panel.

Loading and Enroute Inspections

Alarm Codes

Jump Starting Procedures

Specifications

Warranty Information

Maintenance Inspection Schedule