Do you have a question about the Thermo Ramsey MINI 11-100P and is the answer not in the manual?
General overview of the manual's content and scope.
Detailed specifications for power supply, transducer, indicator, memory, inputs, outputs, and environment.
Information on optional serial communication and serial output boards.
Overview of available models within the MINI product line.
Thermo Ramsey's warranty terms, conditions, and duration.
Procedure for checking the instrument's condition after delivery.
Guidelines for storing the instrument safely before installation.
Recommendations for selecting the optimal mounting location and orientation.
Instructions for proper wiring and connecting the instrument's terminals.
Proper utilization of the sensing function for load cell voltage.
Guidance on selecting and verifying the correct supply voltage.
Steps for cleaning the instrument after installation and wiring.
Default scale parameters and information sources.
Procedure for accessing and modifying instrument setup parameters.
Setting the maximum weight capacity of the scale.
Selecting the desired unit of measurement for the scale.
Defining the resolution or smallest increment of the scale.
Recommended weight for calibration purposes.
Overview of the scale calibration process.
Procedure for calibrating the zero point of the scale.
Steps for span calibration using physical weights.
Method for span calibration using a precision resistor.
Adjusting the filter to reduce oscillations caused by vibrations.
Description of available keyboard protection modes.
Default code for accessing instrument functions.
Steps to activate or deactivate keyboard protection.
Procedure to change the security password.
Description of functions assigned to front panel keys during normal operation.
Functionality of the tare key for setting and resetting tare values.
Overview of control functions for instrument verification.
Table identifying causes of instrument alarms.
Options for alarm actions (no action or cumulative output).
Procedure to clear active alarms.
Steps to activate or deactivate specific alarm functions.
Overview of auxiliary functions for automation.
Features implemented without additional hardware.
Configuration of four thresholds with various parameters.
Assigning functions to three dry contact inputs.
Assigning functions to four relay outputs.
Automatic zeroing to compensate for drift within a band.
Function to record cumulative weight and count of weighings.
Function to display and save the highest transient weight.
Advanced functions like mA output and serial communication.
Configuration of analog mA output for weight transmission.
Setup for connecting to computers and PLCs via RS423/RS422.
Information on no required preventive maintenance and calibration checks.
| Pressure Range | 0-100 PSI |
|---|---|
| Type | Pressure Gauge |
| Accuracy | +/- 3-2-3% of span ASME Grade B |
| Dial Size | 1.5" |
| Weight | 0.2 lb |