Check the action of your reject device to ensure it is working properly. Inspect the reject-confirm switch. You might also want to increase the reject-confirm time using the detector’s reject-confirm function.
M
Michael CharlesAug 20, 2025
What to do if the Thermo Scientific Metal Detector is not getting a signal from the external speed encoder?
R
Richard MarshallAug 20, 2025
Retest APEX using a test sample and with the belt running; this may clear the fault. If the problem persists, check the functioning of the external speed encoder.
Y
ygutierrezAug 22, 2025
What to do if my Thermo Scientific APEX 300 Metal Detector shows a photo eye fault?
G
George WarrenAug 23, 2025
Check the alignment of the photo eye, ensuring the product is breaking the beam. Also, check for reasons for false triggering, such as metal in the belt. Perform a complete test of the detector, including the reject device.
G
gbarnettAug 25, 2025
What does it mean when my Thermo Scientific APEX 300 Metal Detector shows an excess reject fault?
K
Kelly RichardsonAug 26, 2025
Press Clear Fault. Keep in mind that this fault may be caused by excessive contamination in the product, so examine the rejected product to see whether it is heavily contaminated.
D
danny71Aug 27, 2025
What does it mean when my Thermo Scientific APEX 300 shows a phase limit fault?
K
kenneth93Aug 27, 2025
This may be caused by contaminated product or metal elsewhere in the system. If necessary, check and adjust the phase limits. Inspect for contaminated product and metal elsewhere in the system.
R
Robert CaldwellAug 30, 2025
What to do if my Thermo Scientific Metal Detector has been subjected to lightning?
J
Jeanne JonesAug 30, 2025
Erase the memory.
K
Kenneth HallSep 1, 2025
Why does my Thermo Scientific APEX 300 show AuditCheck fault?
M
Mrs. Katelyn ThomasSep 2, 2025
Make sure that you have set up appropriate fault limits for the AuditCheck function, because the signal produced by your product will vary. Also, verify that the Alarm Limit and Fault Limit have not been inadvertently misapplied.
J
Johnny JensenSep 4, 2025
What to do if my Thermo Scientific APEX 300 QA test light has been ignored?
A
Alexander HoldenSep 4, 2025
Perform a QA test.
G
Glenda StephensSep 7, 2025
What to do if the Thermo Scientific Metal Detector doesn't detect the peak size during QA test?
N
Nicole HernandezSep 7, 2025
Repeat the QA test so the required number of detections are achieved.
J
Joshua JordanSep 9, 2025
How to fix a broken search-head cable connection on my Thermo Scientific Metal Detector?
A
Amy JohnsonSep 9, 2025
Examine the cable connections at both ends to make sure all wires are connected correctly.