EasyManua.ls Logo

Thermo Scientific Sorvall X4 Pro-MD User Manual

Thermo Scientific Sorvall X4 Pro-MD
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Thermo Scientific
Sorvall X Pro / ST Plus Series Centrifuges
Instructions for Use
50158527-d • 08 / 2019

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Thermo Scientific Sorvall X4 Pro-MD and is the answer not in the manual?

Thermo Scientific Sorvall X4 Pro-MD Specifications

General IconGeneral
Maximum Capacity4 x 750 mL
ApplicationClinical, Research
Temperature Range-10°C to +40°C
Control SystemMicroprocessor
Acceleration/Deceleration Profiles9/10
Programs99 programs
Certifications/ComplianceCE, UL
Motor TypeInduction motor
Power Requirements50/60 Hz
Dimensions (W x D x H)71 cm
Weight150 kg

Summary

Thermo Scientific Sorvall X Pro / ST Plus Series Centrifuges

Preface

Intended Use

Specifies the intended applications and purpose of the centrifuge.

Safety Instructions

Outlines critical safety precautions for operating the centrifuge.

1. Transport and Set Up

2. Operation

2. 4. How to Install and Remove a Rotor

Step-by-step guide for installing and removing rotors from the centrifuge.

2. 5. Load the Rotor

Instructions on how to properly load samples into the rotor.

2. 7. Set Basic Centrifugation Parameters

Guide to setting fundamental parameters like speed, time, and temperature.

2. 8. Pre-Temper the Centrifugation Chamber

Instructions for pre-conditioning the centrifuge chamber to a specific temperature.

2. 9. Centrifugation

Detailed steps and options for running the centrifugation process.

2. 10. Aerosol-Tight Applications

Procedures and principles for using aerosol-tight rotors and lids for safe operation.

3. Graphical User Interface

3. 2. Set Basic Centrifugation Parameters

Explains how to configure core centrifugation parameters via the GUI.

3. 3. Pre-Temper the Centrifugation Chamber

Details the process of pre-tempering the chamber using the GUI.

3. 4. Centrifugation

Steps for initiating and managing centrifugation runs via the GUI.

3. 5. Status, Alarms and Alerts

Information on viewing centrifuge status, alarms, and alerts through the GUI.

3. 6. Settings

Accessing and configuring various settings via the GUI.

4. LCD Control Panel

4. 2. Set Basic Centrifugation Parameters

Explains how to set up parameters using the LCD control panel.

4. 3. Programs

Describes how to use the program functions on the LCD control panel.

4. 4. Centrifugation

Steps for running centrifugation using the LCD control panel.

5. Maintenance and Care

6. Troubleshooting

6. 1. Mechanical Emergency Door Release

Procedure for manually opening the lid in case of power failure or malfunction.

6. 3. Troubleshooting by Guide

A table listing common error messages and their corresponding troubleshooting steps.

A. Technical Specifications

A. 1. Sorvall X Pro Series

Technical specifications for the Sorvall X Pro series centrifuges.

A. 2. Sorvall ST Plus Series

Technical specifications for the Sorvall ST Plus series centrifuges.

C. Chemical Compatibility

Chemical Compatibility

Table detailing the compatibility of various chemicals with centrifuge materials.

Related product manuals